{"id":502,"date":"2026-06-05T08:37:33","date_gmt":"2026-06-05T08:37:33","guid":{"rendered":"https:\/\/unicoreelectric.com\/?page_id=502"},"modified":"2026-07-30T16:57:14","modified_gmt":"2026-07-30T08:57:14","slug":"high-voltage-power-transformer","status":"publish","type":"page","link":"https:\/\/unicoreelectric.com\/it\/high-voltage-power-transformer\/","title":{"rendered":"Trasformatore di potenza ad alta tensione"},"content":{"rendered":"<div class=\"gb-element-8707d2f5\">\n<div class=\"gb-element-61274448\">\n<div>\n<div class=\"gb-element-a4aabc42\">\n<div class=\"gb-element-145b5331\">\n<p class=\"gb-text-51e78913\"><span class=\"gb-shape\"><svg t=\"1781160960013\" class=\"icon\" viewbox=\"0 0 1024 1024\" version=\"1.1\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" p-id=\"22701\" data-spm-anchor-id=\"a313x.search_index.0.i10.11513a81reLOvG\" width=\"200\" height=\"200\"><path d=\"M173.056 876.544h656.896v68.096H173.056v-68.096z m0-524.288h656.896v68.096H173.056V352.256z m-120.832 81.92v430.08h899.584v-430.08H52.224z m57.856 418.304h-11.776V446.464h11.776v406.016z m69.12 0h-11.776V446.464H179.2v406.016z m74.24 0h-11.776V446.464h11.776v406.016z m71.68 0h-11.776V446.464h11.776v406.016z m71.68 0h-11.776V446.464h11.776v406.016z m70.656 0H455.68V446.464h11.776v406.016z m74.24 0h-11.776V446.464h11.776v406.016z m74.24 0H604.16V446.464h11.776v406.016z m71.68 0H675.84V446.464h11.776v406.016z m71.68 0H747.52V446.464h11.776v406.016z m71.168 0h-11.776V446.464h11.776v406.016z m73.216 0h-11.776V446.464h11.776v406.016z\" p-id=\"22702\"><\/path><path d=\"M718.336 312.832c-28.672 0-54.784-11.264-74.752-29.184v60.416h149.504V283.648c-19.968 17.92-46.08 29.184-74.752 29.184z\" fill=\"#ffffff\" p-id=\"22703\" data-spm-anchor-id=\"a313x.search_index.0.i11.11513a81reLOvG\" class=\"selected\"><\/path><path d=\"M717.824 97.792c-57.856 0-104.96 47.104-104.96 104.96S659.968 307.2 717.824 307.2s104.96-47.104 104.96-104.96-46.592-104.448-104.96-104.448z m0.512 22.528c45.568 0 81.92 36.864 81.92 81.92s-36.864 81.92-81.92 81.92c-45.568 0-81.92-36.864-81.92-81.92s36.352-81.92 81.92-81.92z\" fill=\"#ffffff\" p-id=\"22704\" data-spm-anchor-id=\"a313x.search_index.0.i9.11513a81reLOvG\" class=\"selected\"><\/path><path d=\"M718.336 128.512c-40.96 0-74.24 33.28-74.24 74.24S677.376 276.48 717.824 276.48c40.96 0 74.24-33.28 74.24-74.24s-33.28-73.728-73.728-73.728z m0 93.184c-10.24 0-18.944-8.704-18.944-18.944s8.704-18.944 18.944-18.944 18.944 8.704 18.944 18.944-8.704 18.944-18.944 18.944z\" fill=\"#ffffff\" p-id=\"22705\" data-spm-anchor-id=\"a313x.search_index.0.i7.11513a81reLOvG\" class=\"selected\"><\/path><path d=\"M704.512 202.24c0 7.68 6.144 13.824 13.824 13.824 7.68 0 13.824-6.144 13.824-13.824 0-7.68-6.144-13.824-13.824-13.824-7.68 0.512-13.824 6.656-13.824 13.824zM217.6 216.064h57.856v127.488H217.6V216.064z m16.896-46.592h24.576v38.4h-24.576v-38.4z m84.48 46.592h57.856v127.488H318.976V216.064z m16.896-46.592h24.576v38.4h-24.576v-38.4z m85.504 46.592h57.856v127.488H421.376V216.064z m16.896-46.592h24.576v38.4h-24.576v-38.4z\" fill=\"#ffffff\" p-id=\"22706\" data-spm-anchor-id=\"a313x.search_index.0.i8.11513a81reLOvG\" class=\"selected\"><\/path><\/svg><\/span><\/p>\n\n\n\n<div class=\"gb-element-db5eaf7f\">\n<h1 class=\"gb-text\">Trasformatore di potenza<\/h1>\n\n\n\n<p class=\"gb-text gb-text-112a0e56\">I trasformatori di potenza ad alta tensione Unicore sono progettati per le reti di trasmissione e distribuzione primaria, con classi di tensione da 35 kV a 750 kV \u2014 coprendo applicazioni di innalzamento, abbassamento e trasmissione su lunga distanza di potenza in cabine elettriche, centrali elettriche, parchi industriali e grandi progetti di energia rinnovabile in tutto il mondo. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Progettati intorno a strutture elettromagnetiche ottimizzate, nuclei in acciaio al silicio di alta qualit\u00e0 e costruzioni rinforzate del serbatoio, i nostri trasformatori di potenza ad alta tensione garantiscono basse perdite, basso rumore, un incremento stabile della temperatura e una forte capacit\u00e0 di sopportazione dei cortocircuiti.<\/p>\n\n\n\n<div class=\"gb-element-3184ef21\">\n<a class=\"gb-text gb-text-9a7f2938\" href=\"#popmake-128\">Richiedi un preventivo gratuito<\/a>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"gb-element-5f76133b\">\n<div class=\"gb-element-a25a709a\">\n<div>\n<div class=\"gb-element-9451000c\">\n<div>\n<span class=\"gb-shape gb-shape-dbc0ea35 gb-shape--divider\"><svg class=\"c-ip-slider__bar\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"488\" height=\"25\" fill=\"inherit\" viewbox=\"0 0 487 25\"><path fill-rule=\"evenodd\" d=\"M474.791 25h-1.664L486.334-.004H488L474.791 25zm-10.222 0l13.21-25.004h1.666L466.235 25h-1.666zm-8.554 0L469.223-.004h1.664L457.68 25h-1.665zm-8.557 0L460.669-.004h1.664L449.123 25h-1.665zm-8.554 0l13.21-25.004h1.666L440.569 25h-1.665zm-8.558 0l13.21-25.004h1.666L432.012 25h-1.666zm-8.554 0l13.21-25.004h1.666L423.457 25h-1.665zm-8.554 0L426.445-.004h1.665L414.903 25h-1.665zm-8.558 0L417.891-.004h1.665L406.345 25h-1.665zm-8.553 0L409.333-.004h1.666L397.791 25h-1.664zm-8.558 0l13.21-25.004h1.665L389.234 25h-1.665zm-8.554 0L392.226-.004h1.665L380.681 25h-1.666zm-8.558 0l13.21-25.004h1.666L372.122 25h-1.665zm-8.553 0l13.21-25.004h1.665L363.569 25h-1.665zm-9.174 0L365.937-.004h1.665L354.394 25h-1.664zm-8.558 0l13.21-25.004h1.666L345.837 25h-1.665zm-8.554 0L348.826-.004h1.664L337.283 25h-1.665zm-8.557 0L340.272-.004h1.664L328.726 25h-1.665zm-8.554 0l13.21-25.004h1.666L320.172 25h-1.665zm-8.559 0L323.159-.004h1.666L311.615 25h-1.667zm-8.553 0l13.21-25.004h1.666L303.06 25h-1.665zm-8.554 0L306.048-.004h1.665L294.506 25h-1.665zm-8.558 0L297.494-.004h1.665L285.948 25h-1.665zm-8.553 0L288.936-.004h1.666L277.394 25h-1.664zm-8.558 0l13.21-25.004h1.665L268.837 25h-1.665zm-8.554 0L271.829-.004h1.665L260.283 25h-1.665zm-8.558 0L263.27-.004h1.666L251.725 25h-1.665zm-8.553 0l13.21-25.004h1.665L243.172 25h-1.665zm-9.886 0L244.828-.004h1.665L233.284 25h-1.663zm-8.559 0L236.273-.004h1.666L224.728 25h-1.666zm-8.554 0L227.716-.004h1.665L216.174 25h-1.666zm-8.556 0l13.21-25.004h1.665L207.617 25h-1.665zm-8.555 0l13.21-25.004h1.666L199.062 25h-1.665zm-8.558 0L202.05-.004h1.665L190.505 25h-1.666zm-8.553 0l13.21-25.004h1.665L181.951 25h-1.665zm-8.555 0L184.939-.004h1.664L173.397 25h-1.666zm-8.557 0L176.385-.004h1.664L164.839 25h-1.665zm-8.554 0L167.827-.004h1.665L156.285 25h-1.665zm-8.558 0l13.21-25.004h1.666L147.728 25h-1.666zm-8.554 0L150.719-.004h1.665L139.174 25h-1.666zm-8.557 0l13.21-25.004h1.666L130.615 25h-1.664zm-8.554 0L133.608-.004h1.664L122.062 25h-1.665zm-9.174 0L124.431-.004h1.665L112.887 25h-1.664zm-8.558 0L115.876-.004h1.666L104.331 25h-1.666zm-8.554 0L107.319-.004h1.665L95.777 25h-1.666zm-8.556 0L98.765-.004h1.665L87.219 25h-1.664zM77 25L90.21-.004h1.666L78.665 25H77zm-8.558 0L81.653-.004h1.665L70.108 25h-1.666zm-8.554 0L73.099-.004h1.665L61.554 25h-1.666zm-8.554 0L64.541-.004h1.665L53 25h-1.666zm-8.557 0L55.988-.004h1.664L44.442 25h-1.665zm-8.554 0L47.43-.004h1.665L35.888 25h-1.665zm-8.558 0L38.875-.004h1.666L27.331 25h-1.666zm-8.554 0L30.322-.004h1.665L18.777 25h-1.666zm-8.557 0L21.764-.004h1.666L10.218 25H8.554zM0 25L13.21-.004h1.665L1.665 25H0z\"><\/path><\/svg><\/span>\n<\/div>\n\n\n\n<div>\n<span class=\"gb-shape gb-shape-6c44a342 gb-shape--divider\"><svg class=\"c-ip-slider__bar\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"488\" height=\"25\" fill=\"inherit\" viewbox=\"0 0 487 25\"><path fill-rule=\"evenodd\" d=\"M474.791 25h-1.664L486.334-.004H488L474.791 25zm-10.222 0l13.21-25.004h1.666L466.235 25h-1.666zm-8.554 0L469.223-.004h1.664L457.68 25h-1.665zm-8.557 0L460.669-.004h1.664L449.123 25h-1.665zm-8.554 0l13.21-25.004h1.666L440.569 25h-1.665zm-8.558 0l13.21-25.004h1.666L432.012 25h-1.666zm-8.554 0l13.21-25.004h1.666L423.457 25h-1.665zm-8.554 0L426.445-.004h1.665L414.903 25h-1.665zm-8.558 0L417.891-.004h1.665L406.345 25h-1.665zm-8.553 0L409.333-.004h1.666L397.791 25h-1.664zm-8.558 0l13.21-25.004h1.665L389.234 25h-1.665zm-8.554 0L392.226-.004h1.665L380.681 25h-1.666zm-8.558 0l13.21-25.004h1.666L372.122 25h-1.665zm-8.553 0l13.21-25.004h1.665L363.569 25h-1.665zm-9.174 0L365.937-.004h1.665L354.394 25h-1.664zm-8.558 0l13.21-25.004h1.666L345.837 25h-1.665zm-8.554 0L348.826-.004h1.664L337.283 25h-1.665zm-8.557 0L340.272-.004h1.664L328.726 25h-1.665zm-8.554 0l13.21-25.004h1.666L320.172 25h-1.665zm-8.559 0L323.159-.004h1.666L311.615 25h-1.667zm-8.553 0l13.21-25.004h1.666L303.06 25h-1.665zm-8.554 0L306.048-.004h1.665L294.506 25h-1.665zm-8.558 0L297.494-.004h1.665L285.948 25h-1.665zm-8.553 0L288.936-.004h1.666L277.394 25h-1.664zm-8.558 0l13.21-25.004h1.665L268.837 25h-1.665zm-8.554 0L271.829-.004h1.665L260.283 25h-1.665zm-8.558 0L263.27-.004h1.666L251.725 25h-1.665zm-8.553 0l13.21-25.004h1.665L243.172 25h-1.665zm-9.886 0L244.828-.004h1.665L233.284 25h-1.663zm-8.559 0L236.273-.004h1.666L224.728 25h-1.666zm-8.554 0L227.716-.004h1.665L216.174 25h-1.666zm-8.556 0l13.21-25.004h1.665L207.617 25h-1.665zm-8.555 0l13.21-25.004h1.666L199.062 25h-1.665zm-8.558 0L202.05-.004h1.665L190.505 25h-1.666zm-8.553 0l13.21-25.004h1.665L181.951 25h-1.665zm-8.555 0L184.939-.004h1.664L173.397 25h-1.666zm-8.557 0L176.385-.004h1.664L164.839 25h-1.665zm-8.554 0L167.827-.004h1.665L156.285 25h-1.665zm-8.558 0l13.21-25.004h1.666L147.728 25h-1.666zm-8.554 0L150.719-.004h1.665L139.174 25h-1.666zm-8.557 0l13.21-25.004h1.666L130.615 25h-1.664zm-8.554 0L133.608-.004h1.664L122.062 25h-1.665zm-9.174 0L124.431-.004h1.665L112.887 25h-1.664zm-8.558 0L115.876-.004h1.666L104.331 25h-1.666zm-8.554 0L107.319-.004h1.665L95.777 25h-1.666zm-8.556 0L98.765-.004h1.665L87.219 25h-1.664zM77 25L90.21-.004h1.666L78.665 25H77zm-8.558 0L81.653-.004h1.665L70.108 25h-1.666zm-8.554 0L73.099-.004h1.665L61.554 25h-1.666zm-8.554 0L64.541-.004h1.665L53 25h-1.666zm-8.557 0L55.988-.004h1.664L44.442 25h-1.665zm-8.554 0L47.43-.004h1.665L35.888 25h-1.665zm-8.558 0L38.875-.004h1.666L27.331 25h-1.666zm-8.554 0L30.322-.004h1.665L18.777 25h-1.666zm-8.557 0L21.764-.004h1.666L10.218 25H8.554zM0 25L13.21-.004h1.665L1.665 25H0z\"><\/path><\/svg><\/span>\n<\/div>\n\n\n\n<div>\n<span class=\"gb-shape gb-shape-973f401c gb-shape--divider\"><svg class=\"c-ip-slider__bar\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"488\" height=\"25\" fill=\"inherit\" viewbox=\"0 0 487 25\"><path fill-rule=\"evenodd\" d=\"M474.791 25h-1.664L486.334-.004H488L474.791 25zm-10.222 0l13.21-25.004h1.666L466.235 25h-1.666zm-8.554 0L469.223-.004h1.664L457.68 25h-1.665zm-8.557 0L460.669-.004h1.664L449.123 25h-1.665zm-8.554 0l13.21-25.004h1.666L440.569 25h-1.665zm-8.558 0l13.21-25.004h1.666L432.012 25h-1.666zm-8.554 0l13.21-25.004h1.666L423.457 25h-1.665zm-8.554 0L426.445-.004h1.665L414.903 25h-1.665zm-8.558 0L417.891-.004h1.665L406.345 25h-1.665zm-8.553 0L409.333-.004h1.666L397.791 25h-1.664zm-8.558 0l13.21-25.004h1.665L389.234 25h-1.665zm-8.554 0L392.226-.004h1.665L380.681 25h-1.666zm-8.558 0l13.21-25.004h1.666L372.122 25h-1.665zm-8.553 0l13.21-25.004h1.665L363.569 25h-1.665zm-9.174 0L365.937-.004h1.665L354.394 25h-1.664zm-8.558 0l13.21-25.004h1.666L345.837 25h-1.665zm-8.554 0L348.826-.004h1.664L337.283 25h-1.665zm-8.557 0L340.272-.004h1.664L328.726 25h-1.665zm-8.554 0l13.21-25.004h1.666L320.172 25h-1.665zm-8.559 0L323.159-.004h1.666L311.615 25h-1.667zm-8.553 0l13.21-25.004h1.666L303.06 25h-1.665zm-8.554 0L306.048-.004h1.665L294.506 25h-1.665zm-8.558 0L297.494-.004h1.665L285.948 25h-1.665zm-8.553 0L288.936-.004h1.666L277.394 25h-1.664zm-8.558 0l13.21-25.004h1.665L268.837 25h-1.665zm-8.554 0L271.829-.004h1.665L260.283 25h-1.665zm-8.558 0L263.27-.004h1.666L251.725 25h-1.665zm-8.553 0l13.21-25.004h1.665L243.172 25h-1.665zm-9.886 0L244.828-.004h1.665L233.284 25h-1.663zm-8.559 0L236.273-.004h1.666L224.728 25h-1.666zm-8.554 0L227.716-.004h1.665L216.174 25h-1.666zm-8.556 0l13.21-25.004h1.665L207.617 25h-1.665zm-8.555 0l13.21-25.004h1.666L199.062 25h-1.665zm-8.558 0L202.05-.004h1.665L190.505 25h-1.666zm-8.553 0l13.21-25.004h1.665L181.951 25h-1.665zm-8.555 0L184.939-.004h1.664L173.397 25h-1.666zm-8.557 0L176.385-.004h1.664L164.839 25h-1.665zm-8.554 0L167.827-.004h1.665L156.285 25h-1.665zm-8.558 0l13.21-25.004h1.666L147.728 25h-1.666zm-8.554 0L150.719-.004h1.665L139.174 25h-1.666zm-8.557 0l13.21-25.004h1.666L130.615 25h-1.664zm-8.554 0L133.608-.004h1.664L122.062 25h-1.665zm-9.174 0L124.431-.004h1.665L112.887 25h-1.664zm-8.558 0L115.876-.004h1.666L104.331 25h-1.666zm-8.554 0L107.319-.004h1.665L95.777 25h-1.666zm-8.556 0L98.765-.004h1.665L87.219 25h-1.664zM77 25L90.21-.004h1.666L78.665 25H77zm-8.558 0L81.653-.004h1.665L70.108 25h-1.666zm-8.554 0L73.099-.004h1.665L61.554 25h-1.666zm-8.554 0L64.541-.004h1.665L53 25h-1.666zm-8.557 0L55.988-.004h1.664L44.442 25h-1.665zm-8.554 0L47.43-.004h1.665L35.888 25h-1.665zm-8.558 0L38.875-.004h1.666L27.331 25h-1.666zm-8.554 0L30.322-.004h1.665L18.777 25h-1.666zm-8.557 0L21.764-.004h1.666L10.218 25H8.554zM0 25L13.21-.004h1.665L1.665 25H0z\"><\/path><\/svg><\/span>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"gb-element-6f17dec9\">\n<div class=\"gb-element-c154087b\">\n<p class=\"gb-text-fee061c1\"><span class=\"gb-shape\"><svg t=\"1780481822368\" class=\"icon\" viewbox=\"0 0 1024 1024\" version=\"1.1\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" p-id=\"22267\" width=\"200\" height=\"200\"><path d=\"M891.1 580.9c-25.5 0-47.5 13.9-59.4 34.5H705.6l-99.8-199.5L529 697.5l-51.6-567.8-67.6-5.8-131 491.3H64v68.9h267.7l94.6-354.9 51.3 564.7 67.6 5.9 79.6-292 38.1 76.2h168.8c11.9 20.5 33.9 34.5 59.4 34.5 38 0 68.9-30.9 68.9-68.9 0-38-30.9-68.7-68.9-68.7z\" p-id=\"22268\"><\/path><\/svg><\/span><span class=\"gb-text\">Soluzioni personalizzate per trasformatori<\/span><\/p>\n\n\n\n<p class=\"gb-text-9c707e37\"><span class=\"gb-shape\"><svg t=\"1780481822368\" class=\"icon\" viewbox=\"0 0 1024 1024\" version=\"1.1\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" p-id=\"22267\" width=\"200\" height=\"200\"><path d=\"M891.1 580.9c-25.5 0-47.5 13.9-59.4 34.5H705.6l-99.8-199.5L529 697.5l-51.6-567.8-67.6-5.8-131 491.3H64v68.9h267.7l94.6-354.9 51.3 564.7 67.6 5.9 79.6-292 38.1 76.2h168.8c11.9 20.5 33.9 34.5 59.4 34.5 38 0 68.9-30.9 68.9-68.9 0-38-30.9-68.7-68.9-68.7z\" p-id=\"22268\"><\/path><\/svg><\/span><\/p>\n<\/div>\n\n\n\n<div class=\"gb-element-a87feefc\">\n<div class=\"gb-element-0a177672\">\n<div class=\"gb-element-9e945fea\">\n<div class=\"gb-element-db64d4aa\">\n<p class=\"gb-text-f0993406\"><span class=\"gb-shape\"><svg t=\"1781160960013\" class=\"icon\" viewbox=\"0 0 1024 1024\" version=\"1.1\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" p-id=\"22701\" data-spm-anchor-id=\"a313x.search_index.0.i10.11513a81reLOvG\" width=\"200\" height=\"200\"><path d=\"M173.056 876.544h656.896v68.096H173.056v-68.096z m0-524.288h656.896v68.096H173.056V352.256z m-120.832 81.92v430.08h899.584v-430.08H52.224z m57.856 418.304h-11.776V446.464h11.776v406.016z m69.12 0h-11.776V446.464H179.2v406.016z m74.24 0h-11.776V446.464h11.776v406.016z m71.68 0h-11.776V446.464h11.776v406.016z m71.68 0h-11.776V446.464h11.776v406.016z m70.656 0H455.68V446.464h11.776v406.016z m74.24 0h-11.776V446.464h11.776v406.016z m74.24 0H604.16V446.464h11.776v406.016z m71.68 0H675.84V446.464h11.776v406.016z m71.68 0H747.52V446.464h11.776v406.016z m71.168 0h-11.776V446.464h11.776v406.016z m73.216 0h-11.776V446.464h11.776v406.016z\" p-id=\"22702\"><\/path><path d=\"M718.336 312.832c-28.672 0-54.784-11.264-74.752-29.184v60.416h149.504V283.648c-19.968 17.92-46.08 29.184-74.752 29.184z\" fill=\"#0a3aa3\" p-id=\"22703\" data-spm-anchor-id=\"a313x.search_index.0.i11.11513a81reLOvG\" class=\"selected\"><\/path><path d=\"M717.824 97.792c-57.856 0-104.96 47.104-104.96 104.96S659.968 307.2 717.824 307.2s104.96-47.104 104.96-104.96-46.592-104.448-104.96-104.448z m0.512 22.528c45.568 0 81.92 36.864 81.92 81.92s-36.864 81.92-81.92 81.92c-45.568 0-81.92-36.864-81.92-81.92s36.352-81.92 81.92-81.92z\" fill=\"#0a3aa3\" p-id=\"22704\" data-spm-anchor-id=\"a313x.search_index.0.i9.11513a81reLOvG\" class=\"selected\"><\/path><path d=\"M718.336 128.512c-40.96 0-74.24 33.28-74.24 74.24S677.376 276.48 717.824 276.48c40.96 0 74.24-33.28 74.24-74.24s-33.28-73.728-73.728-73.728z m0 93.184c-10.24 0-18.944-8.704-18.944-18.944s8.704-18.944 18.944-18.944 18.944 8.704 18.944 18.944-8.704 18.944-18.944 18.944z\" fill=\"#0a3aa3\" p-id=\"22705\" data-spm-anchor-id=\"a313x.search_index.0.i7.11513a81reLOvG\" class=\"selected\"><\/path><path d=\"M704.512 202.24c0 7.68 6.144 13.824 13.824 13.824 7.68 0 13.824-6.144 13.824-13.824 0-7.68-6.144-13.824-13.824-13.824-7.68 0.512-13.824 6.656-13.824 13.824zM217.6 216.064h57.856v127.488H217.6V216.064z m16.896-46.592h24.576v38.4h-24.576v-38.4z m84.48 46.592h57.856v127.488H318.976V216.064z m16.896-46.592h24.576v38.4h-24.576v-38.4z m85.504 46.592h57.856v127.488H421.376V216.064z m16.896-46.592h24.576v38.4h-24.576v-38.4z\" fill=\"#0a3aa3\" p-id=\"22706\" data-spm-anchor-id=\"a313x.search_index.0.i8.11513a81reLOvG\" class=\"selected\"><\/path><\/svg><\/span><\/p>\n<\/div>\n\n\n\n<div>\n<p class=\"gb-text gb-text-0cd901df\">Tensione: 35\u2013750 kV<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"gb-element-02258e69\">\n<div class=\"gb-element-155e0ec2\">\n<div class=\"gb-element-96e5a800\">\n<div class=\"gb-element-f3c9bfce\">\n<p class=\"gb-text-2b5134a5\"><span class=\"gb-shape\"><svg t=\"1780898940360\" class=\"icon\" viewbox=\"0 0 1024 1024\" version=\"1.1\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" p-id=\"33372\" width=\"200\" height=\"200\"><path d=\"M960 576v-128l-110.592-36.864c-7.168-23.04-16.384-45.568-27.648-66.56L873.984 240.64 783.36 150.016l-104.448 52.224c-20.992-11.264-43.008-20.48-66.56-27.648l-36.864-110.592h-128l-36.864 110.592c-23.04 6.656-45.056 15.872-66.56 27.648L240.64 150.016 150.016 240.64l52.224 104.448c-11.264 20.992-20.48 43.008-27.648 66.56l-110.592 36.864v128l110.592 36.864c6.656 23.04 15.872 45.056 27.648 66.048L150.016 783.36 240.64 873.984l104.448-52.224c20.992 11.264 43.52 20.48 66.56 27.648l36.864 110.592h128l36.864-110.592c23.04-6.656 45.056-15.872 66.56-27.648l104.448 52.224 90.624-90.624-52.224-104.448c11.264-20.992 20.48-43.52 27.648-66.56l109.568-36.352z m-293.888-97.28l-185.344 262.656c-2.048 2.048-4.096 3.072-6.656 3.072-1.536 0-2.048-0.512-3.072-1.024-4.608-1.536-6.144-4.096-4.608-7.68l29.696-176.64H365.568c-3.072 0-5.632-1.536-6.656-4.096-2.048-2.56-1.536-5.632 1.024-8.704l200.704-262.656c2.56-4.096 5.632-4.608 8.704-2.048 3.072 0.512 4.608 3.072 4.608 7.68L544.256 465.92h114.688c3.072 0 5.632 1.536 6.656 4.096 1.024 2.56 1.024 5.12 0.512 8.704z\" p-id=\"33373\" fill=\"#0a3aa3\"><\/path><\/svg><\/span><\/p>\n<\/div>\n\n\n\n<div>\n<p class=\"gb-text gb-text-3161f69c\">Potenza nominale: 200\u201380.000 kVA<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"gb-element-394c284a\">\n<div class=\"gb-element-c6f41899\">\n<div class=\"gb-element-54adbaae\">\n<div class=\"gb-element-aeeb6fbd\">\n<p class=\"gb-text-ec148ce6\"><span class=\"gb-shape\"><svg t=\"1780898833356\" class=\"icon\" viewbox=\"0 0 1152 1024\" version=\"1.1\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" p-id=\"29644\" width=\"200\" height=\"200\"><path d=\"M96 0C42.944 0 0 41.6 0 93.12V977.472c0 25.664 21.504 46.528 48 46.528h1056c26.496 0 48-20.864 48-46.528V93.12C1152 41.6 1109.056 0 1056 0h-960z m0 232.704h960v698.24h-960V232.64zM576 325.824c-34.048 0-53.12 22.4-64.384 39.68-11.264 17.152-18.816 36.096-26.176 57.664-14.72 43.136-26.688 96.384-37.952 149.184-5.632 26.24-10.432 46.4-15.552 70.528-1.6-8.32-3.2-14.08-4.8-22.592-7.424-40.512-14.464-81.472-22.144-114.304a283.072 283.072 0 0 0-13.12-43.776 81.024 81.024 0 0 0-11.968-21.376 54.848 54.848 0 0 0-43.904-21.952 64 64 0 0 0-46.08 20.224 117.888 117.888 0 0 0-18.56 24.96c-9.728 16.576-17.664 34.176-26.048 50.56a225.92 225.92 0 0 1-23.808 38.912c-3.008 3.584-4.352 4.608-4.736 4.992H192a48.32 48.32 0 0 0-42.112 23.04 45.312 45.312 0 0 0 0 46.976 48.32 48.32 0 0 0 42.112 23.04h27.968c34.304 0 59.584-20.096 75.456-38.592 11.008-12.8 17.664-26.304 24.96-39.68 4.096 21.12 7.936 39.616 12.224 63.168 7.488 40.96 15.36 82.304 24.768 116.096 4.736 16.832 9.408 31.616 16.96 45.888 3.84 7.104 8.128 14.4 16.256 22.144a61.12 61.12 0 0 0 41.408 17.216c23.232 0 37.76-13.248 44.992-21.888 7.296-8.704 11.008-16.256 14.528-24.192a352.64 352.64 0 0 0 17.728-54.592c10.816-41.472 21.12-93.952 32.256-145.92 10.56-49.472 21.888-97.088 33.344-132.224 6.72 24.576 13.376 52.288 19.456 84.608 7.552 40.512 14.784 81.856 24.96 116.48 5.12 17.28 10.496 32.896 20.096 48.256s29.44 36.352 60.032 36.352c23.872 0 43.136-12.48 54.848-24.448 11.712-11.904 19.2-24.64 25.92-38.08 13.568-26.88 23.36-57.408 32.384-87.296 4.032-13.312 7.04-22.656 10.688-34.88 7.872 16 15.808 32.64 25.664 48 5.44 8.384 11.264 16.448 20.16 24.704 8.96 8.32 23.232 18.944 45.312 18.944H960a48.32 48.32 0 0 0 42.112-23.04 45.312 45.312 0 0 0 0-46.976 48.32 48.32 0 0 0-42.112-23.04h-29.696a508.352 508.352 0 0 1-23.04-43.328c-8.512-17.408-17.28-35.776-27.968-52.48a121.152 121.152 0 0 0-19.84-24.768 64.32 64.32 0 0 0-45.44-19.136 58.56 58.56 0 0 0-38.144 14.72c-7.488 6.656-11.52 12.672-14.912 18.432-6.848 11.392-11.072 22.336-15.488 34.56-8.704 24.576-16.512 53.76-25.088 82.112-4.672 15.424-9.472 26.24-14.336 39.552-5.76-24.448-11.52-50.368-17.344-81.344-7.68-40.96-15.488-82.56-27.392-118.016-5.952-17.664-12.544-33.92-23.936-49.472-11.328-15.488-33.024-33.6-61.376-33.6z\" fill=\"#0a3aa3\" p-id=\"29645\"><\/path><\/svg><\/span><\/p>\n<\/div>\n\n\n\n<div>\n<p class=\"gb-text gb-text-f4eec352\">Frequenza: 50\/60 Hz<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div>\n<div class=\"gb-element-4609fbf9\">\n<div>\n<p class=\"gb-text gb-text-1cb0c9d6\">Accedi a soluzioni di trasformatori di alta qualit\u00e0 per elevare i tuoi progetti energetici<\/p>\n\n\n\n<h2 class=\"gb-text gb-text-0e286594\">Affidabili trasformatori di potenza ad alta tensione in vendita<\/h2>\n\n\n\n<img decoding=\"async\" class=\"gb-media-c1f0bfda\" alt=\"\" title=\"2\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/2-1.png\"\/>\n\n\n\n<div class=\"gb-element-467c7b2c\">\n<div class=\"gb-element-fbdfbab0\">\n<div>\n<div class=\"gb-element-1ace05b2 box-shadow\">\n<img decoding=\"async\" class=\"gb-media-74228011\" alt=\"\" title=\"trasformatore-alta-tensione-in-vendita\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/high-voltage-power-transformer-for-sale.png\"\/>\n<\/div>\n<\/div>\n\n\n\n<div>\n<div class=\"gb-element-e0ecae5d box-shadow\">\n<div class=\"gb-element-d52ebc8c\">\n<h3 class=\"gb-text\">Miglior prezzo per trasformatori di potenza ad alta e altissima tensione<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">I nostri trasformatori di potenza ad alta tensione sono disponibili in potenze nominali standard da 200 kVA a 80.000 kVA, con classi di tensione comprese tra 35 kV e 750 kV \u2014 inclusi 66 kV, 110 kV, 132 kV, 220 kV, 330 kV, 400 kV e 500 kV. Campo di regolazione del rapporto di trasformazione, tensione media, tensione bassa, gruppo di collegamento, perdite a vuoto, perdite a carico e impedenza di cortocircuito sono tutti configurabili in base alle specifiche esigenze del tuo progetto e della rete.<\/p>\n\n\n\n<div class=\"gb-element-4850bce6\">\n<p class=\"gb-text-018fd796\"><span class=\"gb-shape\"><svg t=\"1780484448089\" class=\"icon\" viewbox=\"0 0 1024 1024\" version=\"1.1\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" p-id=\"24191\" width=\"200\" height=\"200\"><path d=\"M771.3 465.8L256 1024l150.1-450.3c1.7-5.2-2.1-10.5-7.6-10.5H253c-46.5 0-77.5-48.1-58.3-90.5L392.5 37.5C402.9 14.7 425.7 0 450.8 0h419.6L672.5 346.4c-3 5.3 0.8 12 6.9 12h44.8c55.8 0 84.9 66.4 47.1 107.4z\" p-id=\"24192\"><\/path><\/svg><\/span><span class=\"gb-text\">Incremento stabile della temperatura durante il funzionamento continuo a pieno carico<\/span><\/p>\n\n\n\n<p class=\"gb-text-82ee530d\"><span class=\"gb-shape\"><svg t=\"1780484448089\" class=\"icon\" viewbox=\"0 0 1024 1024\" version=\"1.1\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" p-id=\"24191\" width=\"200\" height=\"200\"><path d=\"M771.3 465.8L256 1024l150.1-450.3c1.7-5.2-2.1-10.5-7.6-10.5H253c-46.5 0-77.5-48.1-58.3-90.5L392.5 37.5C402.9 14.7 425.7 0 450.8 0h419.6L672.5 346.4c-3 5.3 0.8 12 6.9 12h44.8c55.8 0 84.9 66.4 47.1 107.4z\" p-id=\"24192\"><\/path><\/svg><\/span><span class=\"gb-text\">Progettazione elettromagnetica ottimizzata per ridurre le perdite a vuoto e a carico<\/span><\/p>\n\n\n\n<p class=\"gb-text-c7aa0090\"><span class=\"gb-shape\"><svg t=\"1780484448089\" class=\"icon\" viewbox=\"0 0 1024 1024\" version=\"1.1\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" p-id=\"24191\" width=\"200\" height=\"200\"><path d=\"M771.3 465.8L256 1024l150.1-450.3c1.7-5.2-2.1-10.5-7.6-10.5H253c-46.5 0-77.5-48.1-58.3-90.5L392.5 37.5C402.9 14.7 425.7 0 450.8 0h419.6L672.5 346.4c-3 5.3 0.8 12 6.9 12h44.8c55.8 0 84.9 66.4 47.1 107.4z\" p-id=\"24192\"><\/path><\/svg><\/span><span class=\"gb-text\">Nucleo in acciaio al silicio CRGO di alta qualit\u00e0 per una conversione energetica efficiente<\/span><\/p>\n\n\n\n<p class=\"gb-text-0984fcc1\"><span class=\"gb-shape\"><svg t=\"1780484448089\" class=\"icon\" viewbox=\"0 0 1024 1024\" version=\"1.1\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" p-id=\"24191\" width=\"200\" height=\"200\"><path d=\"M771.3 465.8L256 1024l150.1-450.3c1.7-5.2-2.1-10.5-7.6-10.5H253c-46.5 0-77.5-48.1-58.3-90.5L392.5 37.5C402.9 14.7 425.7 0 450.8 0h419.6L672.5 346.4c-3 5.3 0.8 12 6.9 12h44.8c55.8 0 84.9 66.4 47.1 107.4z\" p-id=\"24192\"><\/path><\/svg><\/span><span class=\"gb-text\">Costruzione rinforzata del serbatoio con forte capacit\u00e0 di sopportazione dei cortocircuiti<\/span><\/p>\n\n\n\n<p class=\"gb-text-b154b1b6\"><span class=\"gb-shape\"><svg t=\"1780484448089\" class=\"icon\" viewbox=\"0 0 1024 1024\" version=\"1.1\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" p-id=\"24191\" width=\"200\" height=\"200\"><path d=\"M771.3 465.8L256 1024l150.1-450.3c1.7-5.2-2.1-10.5-7.6-10.5H253c-46.5 0-77.5-48.1-58.3-90.5L392.5 37.5C402.9 14.7 425.7 0 450.8 0h419.6L672.5 346.4c-3 5.3 0.8 12 6.9 12h44.8c55.8 0 84.9 66.4 47.1 107.4z\" p-id=\"24192\"><\/path><\/svg><\/span><span class=\"gb-text\">Progettazione a basso rumore adatta per cabine elettriche e ambienti urbani<\/span><\/p>\n\n\n\n<p class=\"gb-text-da45fb13\"><span class=\"gb-shape\"><svg t=\"1780484448089\" class=\"icon\" viewbox=\"0 0 1024 1024\" version=\"1.1\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" p-id=\"24191\" width=\"200\" height=\"200\"><path d=\"M771.3 465.8L256 1024l150.1-450.3c1.7-5.2-2.1-10.5-7.6-10.5H253c-46.5 0-77.5-48.1-58.3-90.5L392.5 37.5C402.9 14.7 425.7 0 450.8 0h419.6L672.5 346.4c-3 5.3 0.8 12 6.9 12h44.8c55.8 0 84.9 66.4 47.1 107.4z\" p-id=\"24192\"><\/path><\/svg><\/span><span class=\"gb-text\">Sistema di isolamento affidabile progettato per una lunga vita operativa<\/span><\/p>\n<\/div>\n\n\n\n<div class=\"gb-element-099a73e0\">\n<a class=\"gb-text gb-text-3af8c030\" href=\"#popmake-128\">Richiedi subito un preventivo<\/a>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div>\n<div class=\"gb-element-94a42d01\">\n<div>\n<p class=\"gb-text gb-text-2ffdd071\">Specifiche campione del trasformatore di potenza a 110 kV \u2014 dati completi per tutte le serie disponibili su richiesta<\/p>\n\n\n\n<h2 class=\"gb-text gb-text-7c64ce6b\">Specifiche tecniche<\/h2>\n\n\n\n<img decoding=\"async\" class=\"gb-media-682eda07\" alt=\"\" title=\"2\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/2-1.png\"\/>\n\n\n\n<div class=\"gb-element-8f3ec5ad\">\n<figure class=\"wp-block-table\"><table><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"2\">Potenza nominale (kVA)<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"4\">Combinazione di tensioni e campo di regolazione del rapporto di trasformazione<\/td><td rowspan=\"2\">Gruppo di collegamento<\/td><td rowspan=\"2\">Perdite a vuoto (kW)<\/td><td rowspan=\"2\">Perdite a carico (kW)<\/td><td rowspan=\"2\">Corrente a vuoto (%)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Tensione alta (kV)<\/td><td class=\"has-text-align-center\" data-align=\"center\">Campo di regolazione della tensione alta (%)<\/td><td>Tensione media (kV)<\/td><td>Tensione bassa (kV)<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">6300<\/td><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"11\">110<\/td><td rowspan=\"11\">\u00b14\u00d71,25<br>\u00b16\u00d71,25<br>\u00b18\u00d71,25<\/td><td rowspan=\"11\">36<br>37<br>38.5<\/td><td rowspan=\"11\">6.3<br>6.6<br>10.5<br>21<\/td><td rowspan=\"11\">YNyn0dl1<\/td><td>7.7<\/td><td>42<\/td><td>0.61<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">8000<\/td><td class=\"has-text-align-center\" data-align=\"center\">9.2<\/td><td>50<\/td><td>0.61<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">10000<\/td><td class=\"has-text-align-center\" data-align=\"center\">10.9<\/td><td>59<\/td><td>0.57<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">12500<\/td><td class=\"has-text-align-center\" data-align=\"center\">12.9<\/td><td>70<\/td><td>0.57<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">16000<\/td><td class=\"has-text-align-center\" data-align=\"center\">15.4<\/td><td>86<\/td><td>0.54<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">20000<\/td><td class=\"has-text-align-center\" data-align=\"center\">18.2<\/td><td>101<\/td><td>0.54<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">25000<\/td><td class=\"has-text-align-center\" data-align=\"center\">21.6<\/td><td>120<\/td><td>0.5<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">31500<\/td><td class=\"has-text-align-center\" data-align=\"center\">25.7<\/td><td>142<\/td><td>0.5<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">40000<\/td><td class=\"has-text-align-center\" data-align=\"center\">308<\/td><td>170<\/td><td>0.46<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">50000<\/td><td class=\"has-text-align-center\" data-align=\"center\">36.4<\/td><td>202<\/td><td>0.46<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">63000<\/td><td class=\"has-text-align-center\" data-align=\"center\">43.3<\/td><td>243<\/td><td>0.42<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"9\">Attualmente vengono forniti prodotti con struttura di abbassamento. Altre combinazioni di tensione possono essere fornite su richiesta dell\u2019utente.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br>La ripartizione della potenza tra gli avvolgimenti ad alta, media e bassa tensione \u00e8 (100\/100\/100)%.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br>Su richiesta dell\u2019utente, il gruppo di collegamento pu\u00f2 essere anche YNdl1y10.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br>Su richiesta dell\u2019utente, la tensione media pu\u00f2 assumere valori diversi da quelli indicati nella tabella o essere dotata di regolatore di presa.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br>In condizioni operative, \u00e8 preferibile un numero minore di posizioni di regolazione.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n\n\n\n<div class=\"gb-element-5b150d50\">\n<a class=\"gb-text gb-text-1cfd3b3d\" href=\"#popmake-128\">Personalizza le tue soluzioni per trasformatori<\/a>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div>\n<div class=\"gb-element-317ec195\">\n<div>\n<div>\n<p class=\"gb-text gb-text-f537db71\">Scopri i vantaggi fondamentali dei trasformatori per ottimizzare la tua configurazione energetica<\/p>\n\n\n\n<h2 class=\"gb-text gb-text-38fb1e57\">Vantaggi eccezionali del trasformatore di potenza ad alta tensione Unicore<\/h2>\n\n\n\n<img decoding=\"async\" class=\"gb-media-bc4c2ec9\" alt=\"\" title=\"2\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/2-1.png\"\/>\n\n\n\n<div class=\"gb-element-25803580\">\n<div class=\"gb-element-fb6a0a63\">\n<div>\n<div class=\"gb-element-1b65f619 box-shadow\">\n<h3 class=\"gb-text\">Progettazione elettromagnetica ottimizzata<\/h3>\n\n\n\n<p class=\"gb-text\">Ogni trasformatore di potenza ad alta tensione Unicore \u00e8 progettato con una struttura elettromagnetica ottimizzata che minimizza la densit\u00e0 di flusso, riduce le perdite nel nucleo e migliora l\u2019efficienza complessiva della conversione energetica \u2014 garantendo una riduzione misurabile delle perdite a vuoto che si traduce direttamente in costi operativi inferiori durante l\u2019intero ciclo di vita della tua cabina elettrica o rete di trasmissione.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div>\n<div class=\"gb-element-09ac0972 box-shadow\">\n<h3 class=\"gb-text\">Configurazioni di innalzamento e abbassamento<\/h3>\n\n\n\n<p class=\"gb-text\">I trasformatori ad alta tensione Unicore sono disponibili sia in configurazione di innalzamento che di abbassamento, supportando i collegamenti dei generatori nelle centrali elettriche, i punti di immissione nella rete di trasmissione, la conversione di tensione nelle cabine primarie e l\u2019alimentazione industriale ad alta tensione \u2014 coprendo ogni esigenza di flusso di potenza, in entrambi i versi, nell\u2019ambito del tuo progetto.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div>\n<div class=\"gb-element-51f518c3 box-shadow\">\n<h3 class=\"gb-text\">Costruzione rinforzata del serbatoio<\/h3>\n\n\n\n<p class=\"gb-text\">Ogni serbatoio dei trasformatori ad alta tensione Unicore \u00e8 progettato con una struttura in acciaio rinforzata per resistere alle sollecitazioni meccaniche causate da cortocircuiti, dai carichi di trasporto e dalla pressione operativa a lungo termine \u2014 assicurando integrit\u00e0 strutturale e protezione degli elementi attivi per tutta la durata di servizio del trasformatore in ambienti impegnativi come le cabine elettriche.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div>\n<div class=\"gb-element-2071c11b box-shadow\">\n<h3 class=\"gb-text\">Pronto per progetti di energia rinnovabile<\/h3>\n\n\n\n<p class=\"gb-text\">I nostri trasformatori di potenza ad alta tensione sono sempre pi\u00f9 scelti per grandi progetti solari, eolici e idroelettrici \u2014 dove i trasformatori per il collegamento alla rete devono soddisfare requisiti precisi relativi al rapporto di trasformazione, alla tolleranza alle armoniche e alle prestazioni in termini di perdite. Il nostro team di ingegneri ha maturato esperienza nel supporto agli sviluppatori di energia rinnovabile su pi\u00f9 continenti e in conformit\u00e0 a diversi standard di rete.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div>\n<div class=\"gb-element-762d30b4 box-shadow\">\n<h3 class=\"gb-text\">Forte capacit\u00e0 di sopportazione dei cortocircuiti<\/h3>\n\n\n\n<p class=\"gb-text\">I trasformatori ad alta tensione Unicore sono progettati e collaudati per resistere alle sollecitazioni dinamiche e termiche complete derivanti da condizioni di cortocircuito \u2014 proteggendo il vostro investimento nella sottostazione e garantendo la continuit\u00e0 della rete anche negli scenari di guasto pi\u00f9 severi che il vostro sistema di protezione della rete pu\u00f2 incontrare.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div>\n<div class=\"gb-element-947c6944 box-shadow\">\n<h3 class=\"gb-text\">Prestazioni stabili dell\u2019incremento di temperatura<\/h3>\n\n\n\n<p class=\"gb-text\">La nostra progettazione termica garantisce un incremento di temperatura stabile e controllato durante il funzionamento continuo a pieno carico \u2014 con sistemi di raffreddamento configurati per mantenere le temperature degli avvolgimenti e dell\u2019olio entro i limiti previsti dalla norma IEC 60076, prolungando la vita dell\u2019isolamento e riducendo il rischio di degrado termico durante l\u2019intera vita operativa del trasformatore.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"gb-element-7aa74abb\">\n<a class=\"gb-text gb-text-fdd27c87\" href=\"#popmake-128\">Richiedi subito il prezzo aggiornato<\/a>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"gb-element-01ecdc67\">\n<div class=\"gb-element-fe7e0d5c\">\n<div>\n<div class=\"gb-element-9b0779e6\">\n<div>\n<div>\n<p class=\"gb-text-3f918e64\"><span class=\"gb-text\">30+<\/span><span class=\"gb-shape\"><svg t=\"1780882371535\" class=\"icon\" viewbox=\"0 0 1024 1024\" version=\"1.1\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" p-id=\"6813\" width=\"200\" height=\"200\"><path d=\"M502.938 470.289c0.968 0.541 1.935 0.967 3.109 1.509l0.967 0.207c5.25 1.186 10.189 0.426 15.014-1.716l0.207-0.426 5.688-2.142 0.54-0.219h0.427c38.81-12.112 70.228-31.407 95.845-56.608 27.666-27.125 48.572-60.893 62.826-97.987 3.868-10.512-0.956-21.99-11.363-25.743-10.499-4.283-22.186 0.967-26.157 11.375-12.653 31.626-30.015 60.673-53.604 83.837-20.908 20.367-46.858 36.564-79.232 46.535l-0.968 0.53-2.36 0.426-1.934 0.967-1.819-0.967-1.393-0.426-1.923-0.53c-31.96-9.971-58.324-26.168-79.023-46.535-23.799-23.164-41.171-52.211-53.708-83.837-3.869-10.408-15.761-15.658-25.731-11.375-10.513 3.753-15.232 15.231-11.479 25.743 14.368 37.095 34.734 70.862 62.826 97.987 25.202 25.201 57.149 44.497 95.639 56.608h0.321l0.645 0.219 5.25 2.142 1.39 0.426z\" fill=\"\" p-id=\"6814\"><\/path><path d=\"M820.085 880.92h-28.091c-4.939-102.281-28.092-179.37-61.651-237.154l-0.426-1.186c-35.172-60.466-81.812-99.921-130.8-124.04 48.988-24.443 95.628-63.47 130.8-123.936l0.426-1.083c34.734-60.247 58.542-141.621 62.181-250.556h27.562c18.756 0 33.549-14.689 33.549-33.341 0-18.444-14.793-33.238-33.549-33.238H203.927c-18.549 0-33.561 14.794-33.561 33.238 0 18.651 15.012 33.341 33.561 33.341h27.653c3.972 108.935 27.343 190.309 62.077 250.556l0.645 1.083c35.276 60.466 81.697 99.493 130.915 123.936-49.218 24.119-95.639 63.574-130.915 124.04l-0.645 1.186c-33.341 57.784-56.39 134.873-61.433 237.154h-28.298c-18.549 0-33.561 14.795-33.561 32.813 0 19.077 15.012 33.882 33.561 33.882h616.158c18.756 0 33.549-14.805 33.549-33.882 0.001-18.018-14.792-32.813-33.548-32.813zM287.867 767.703c10.085-40.952 23.809-75.156 40.536-103.675l0.426-1.496c40.422-69.482 97.987-106.575 156.53-124.697l2.36-1.394h0.529c1.187-0.425 2.36-0.967 3.326-1.818l0.428-0.541 1.507-0.968 0.209-0.426 1.391-1.497 0.221-0.438c0.966-0.955 1.495-2.141 2.463-3.315v-0.541c0.864-1.392 1.393-3.005 1.393-4.707l0.219-0.439v-1.495l0.219-1.187v-0.955l-0.219-1.187v-0.967l-0.219-0.853c0-1.715-0.528-3.431-1.393-4.823v-0.426c-0.968-1.509-1.497-2.477-2.463-3.327l-0.221-0.749-1.391-1.186h-0.209l-1.507-1.393-0.428-0.53c-0.966-0.645-2.14-1.394-3.326-2.153l-0.529-0.207-2.36-0.967c-58.543-17.58-116.108-55.216-156.53-125.122l-0.426-0.53c-31.418-54.894-52.866-129.844-56.724-230.731H752.32c-3.327 100.887-24.764 175.837-56.608 230.731l-0.529 0.53c-40.215 69.906-97.998 107.542-156.001 125.122l-2.901 0.967-0.528 0.207c-1.187 0.76-2.142 1.509-3.327 2.153l-0.428 0.53-1.393 1.393-1.715 1.186-0.218 0.749c-0.749 0.851-1.498 1.818-1.923 3.327l-0.438 0.426c-0.53 1.393-0.956 3.108-1.497 4.823v7.083c0.541 1.702 0.967 3.315 1.497 4.707l0.438 0.541c0.425 1.175 1.174 2.36 1.923 3.315l0.218 0.438 1.715 1.497v0.426l1.393 0.968 0.428 0.541c0.967 0.852 2.141 1.394 3.327 1.818h0.528l2.901 1.394c58.003 18.122 115.786 55.215 156.001 124.697l0.529 1.496c16.831 28.519 30.452 106.253 40.422 146.675-22.843-30.015-50.496-54.25-81.373-72.05-43.75-24.982-93.277-37.841-143.025-37.841-49.217 0-98.746 12.858-142.703 38.06-30.232 17.581-55.339 33.762-82.165 59.831l-7 12 7.999-43zM276.504 884.92c29.097-66.845 61.87-81.827 112.688-111.313 37.416-21.874 79.979-32.812 122.543-32.812 43.104 0 85.449 10.938 123.084 32.812 50.818 29.486 64.822 39.542 112.678 107.313l-470.993 4z\" fill=\"\" p-id=\"6815\"><\/path><path d=\"M512 652c19.054 0 34.5-16.342 34.5-36.5S531.054 553 512 553s-34.5 42.342-34.5 62.5S492.946 652 512 652z\" fill=\"\" p-id=\"6816\"><\/path><\/svg><\/span><\/p>\n\n\n\n<p class=\"gb-text gb-text-0c2454b1\">Anni nel settore<\/p>\n\n\n\n<p class=\"gb-text gb-text-87d33508\">Offriamo trasformatori e servizi di altissima qualit\u00e0 in tutto il mondo dal 1993.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div>\n<div>\n<p class=\"gb-text-e4abfdb0\"><span class=\"gb-text\">18+<\/span><span class=\"gb-shape\"><svg t=\"1780882786240\" class=\"icon\" viewbox=\"0 0 1024 1024\" version=\"1.1\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" p-id=\"21974\" width=\"200\" height=\"200\"><path d=\"M784.8 64.1H242.6c-30.7 0-55.7 24.9-55.7 55.7v180.5c0 18.6 9.3 36 24.8 46.3l177.1 117.9C306.6 509 250.6 596.1 250.6 696c0 145.1 118 263.1 263.1 263.1 145 0 263-118 263-263.1 0-99.9-56-186.9-138.2-231.5l177.1-117.9c15.5-10.3 24.8-27.7 24.8-46.3V119.8c0-30.8-24.9-55.7-55.6-55.7z m-63.8 632c0 114.6-92.8 207.4-207.4 207.4-114.6 0-207.4-92.8-207.4-207.4 0-114.5 92.8-207.4 207.4-207.4 114.6 0 207.4 92.9 207.4 207.4z m63.8-395.8L678.7 371V265c0-10.2-8.3-18.5-18.6-18.5-10.2 0-18.6 8.3-18.6 18.5v130.7l-66.9 44.6c-19.6-4.7-40-7.2-61-7.2s-41.4 2.6-61 7.2L384.5 395V265c0-10.2-8.3-18.5-18.6-18.5s-18.6 8.3-18.6 18.5v105.2l-104.9-69.9V119.8h104.9v49.7c0 10.2 8.3 18.6 18.6 18.6 10.2 0 18.6-8.3 18.6-18.6v-49.7h257v49.7c0 10.2 8.3 18.6 18.6 18.6s18.6-8.3 18.6-18.6v-49.7h106.1v180.5z\" fill=\"#ffffff\" p-id=\"21975\"><\/path><path d=\"M480.4 550.4L449.5 613l-69.1 10c-14 2-25.6 11.8-30 25.3-4.4 13.4-0.7 28.2 9.4 38.1l50 48.7-11.8 68.8c-2.4 13.9 3.3 28 14.8 36.3 6.5 4.7 14.1 7.1 21.8 7.1 5.9 0 11.8-1.4 17.3-4.3l61.8-32.5 61.8 32.5c5.4 2.8 11.4 4.3 17.3 4.3 7.7 0 15.3-2.4 21.8-7.1 11.4-8.3 17.2-22.4 14.8-36.3L617.5 735l50-48.8c10.1-9.9 13.8-24.6 9.4-38-4.4-13.4-16-23.2-30-25.3l-69.1-10-30.8-62.5c-6.3-12.7-19.2-20.7-33.3-20.7-14.1 0-27 8-33.3 20.7z m72.8 96.5l88.4 12.8-64 62.3 15.1 88-79-41.5-79 41.5 15.1-88-63.9-62.3 88.4-12.8 39.5-80.1 39.4 80.1z\" fill=\"#ffffff\" p-id=\"21976\"><\/path><\/svg><\/span><\/p>\n\n\n\n<p class=\"gb-text gb-text-ce38fc68\">Premi internazionali<\/p>\n\n\n\n<p class=\"gb-text gb-text-49e15c4b\">Ricevuti numerosi premi, riconoscimenti e certificati a livello globale.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div>\n<div>\n<p class=\"gb-text-a3d6b853\"><span class=\"gb-text\">2,4k<\/span><span class=\"gb-shape\"><svg t=\"1780882730402\" class=\"icon\" viewbox=\"0 0 1024 1024\" version=\"1.1\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" p-id=\"20423\" width=\"200\" height=\"200\"><path d=\"M885.333333 981.333333H181.333333a53.393333 53.393333 0 0 1-53.333333-53.333333V224a53.393333 53.393333 0 0 1 53.333333-53.333333h53.333334a21.333333 21.333333 0 0 1 0 42.666666h-53.333334a10.666667 10.666667 0 0 0-10.666666 10.666667v704a10.666667 10.666667 0 0 0 10.666666 10.666667h704a10.666667 10.666667 0 0 0 10.666667-10.666667V224a10.666667 10.666667 0 0 0-10.666667-10.666667h-53.333333a21.333333 21.333333 0 0 1 0-42.666666h53.333333a53.393333 53.393333 0 0 1 53.333334 53.333333v704a53.393333 53.393333 0 0 1-53.333334 53.333333z m-522.666666-170.666666a21.266667 21.266667 0 0 1-15.086667-6.246667l-42.666667-42.666667a21.333333 21.333333 0 0 1 30.173334-30.173333l27.58 27.586667 70.246666-70.253334a21.333333 21.333333 0 0 1 30.173334 30.173334l-85.333334 85.333333A21.266667 21.266667 0 0 1 362.666667 810.666667z m384-42.666667H533.333333a21.333333 21.333333 0 0 1 0-42.666667h213.333334a21.333333 21.333333 0 0 1 0 42.666667zM362.666667 640a21.266667 21.266667 0 0 1-15.086667-6.246667l-42.666667-42.666666a21.333333 21.333333 0 0 1 30.173334-30.173334L362.666667 588.5l70.246666-70.253333a21.333333 21.333333 0 0 1 30.173334 30.173333l-85.333334 85.333333A21.266667 21.266667 0 0 1 362.666667 640z m384-42.666667H533.333333a21.333333 21.333333 0 0 1 0-42.666666h213.333334a21.333333 21.333333 0 0 1 0 42.666666zM362.666667 469.333333a21.266667 21.266667 0 0 1-15.086667-6.246666l-42.666667-42.666667a21.333333 21.333333 0 0 1 30.173334-30.173333L362.666667 417.833333l70.246666-70.253333a21.333333 21.333333 0 0 1 30.173334 30.173333l-85.333334 85.333334A21.266667 21.266667 0 0 1 362.666667 469.333333z m384-42.666666H533.333333a21.333333 21.333333 0 0 1 0-42.666667h213.333334a21.333333 21.333333 0 0 1 0 42.666667z m0-170.666667H320a21.333333 21.333333 0 0 1-21.333333-21.333333c0-26.046667 13.273333-50.786667 38.38-71.546667 19.54-16.153333 46.053333-29.666667 77.186666-39.38a129.22 129.22 0 0 1 41.453334-54.84 128 128 0 0 1 155.293333 0 129.22 129.22 0 0 1 41.453333 54.84c31.133333 9.713333 57.653333 23.226667 77.186667 39.38C754.726667 183.88 768 208.62 768 234.666667a21.333333 21.333333 0 0 1-21.333333 21.333333z m-398.38-42.666667h370.093333c-4.493333-6.926667-10.493333-12.82-15.953333-17.333333-17.166667-14.193333-42.14-26.066667-72.226667-34.32a21.333333 21.333333 0 0 1-14.853333-14.666667C604.893333 110.666667 571.166667 85.333333 533.333333 85.333333s-71.56 25.333333-82 61.673334a21.333333 21.333333 0 0 1-14.853333 14.666666c-30.1 8.26-55.073333 20.133333-72.24 34.326667-5.46 4.513333-11.46 10.406667-15.953333 17.333333z\" fill=\"#ffffff\" p-id=\"20424\" data-spm-anchor-id=\"a313x.search_index.0.i16.5e843a81f1WaqK\" class=\"selected\"><\/path><\/svg><\/span><\/p>\n\n\n\n<p class=\"gb-text gb-text-3d178956\">Aiutiamo i progetti a prosperare<\/p>\n\n\n\n<p class=\"gb-text gb-text-d31be8d5\">Supportiamo oltre 2.400 progetti energetici in vari settori in tutto il mondo.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div>\n<div>\n<p class=\"gb-text-50c76c03\"><span class=\"gb-text\">80+<\/span><span class=\"gb-shape\"><svg t=\"1780882850429\" class=\"icon\" viewbox=\"0 0 1024 1024\" version=\"1.1\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" p-id=\"23995\" width=\"200\" height=\"200\"><path d=\"M512 1024C229.6832 1024 0 794.3168 0 512S229.6832 0 512 0s512 229.6832 512 512-229.6832 512-512 512z m0-960C265.0112 64 64 265.0112 64 512S265.0112 960 512 960 960 758.9888 960 512 758.9888 64 512 64z\" p-id=\"23996\" fill=\"#ffffff\"><\/path><path d=\"M200.0896 129.024c-6.656 50.2784 27.648 98.5088 81.1008 95.1296 29.0816-1.8432 52.8384-16.1792 79.6672-25.6 28.4672-10.0352 49.7664-1.7408 72.2944 16.9984 3.2768 2.7648 11.4688 7.68 13.1072 11.6736 1.3312 3.3792 0.7168 1.9456-2.6624 6.5536-8.3968 11.1616-17.6128 20.3776-22.528 33.792-8.6016 23.2448-5.4272 50.5856 8.6016 70.9632 33.4848 48.8448 94.3104 36.0448 144.2816 34.5088 54.4768-1.7408 99.7376 44.8512 70.7584 98.2016-24.1664 44.3392-70.656 77.5168-121.1392 83.7632-31.0272 3.8912-48.9472-7.68-69.5296-29.0816-19.5584-20.3776-40.7552-33.9968-69.12-37.7856-42.496-5.632-116.8384-2.1504-133.632 46.3872-10.0352 29.0816-3.072 66.3552-2.1504 96.5632 0.4096 13.0048 6.656 37.1712-7.0656 44.1344-11.264 5.7344-27.5456 3.584-38.8096-1.024-26.7264-11.0592-39.2192-39.5264-69.9392-44.544-29.184-4.7104-55.296 8.6016-72.0896 31.9488-18.1248 25.088 23.552 49.0496 41.472 24.2688 17.92-24.8832 41.7792 4.9152 56.1152 16.5888 20.6848 16.7936 47.4112 25.8048 74.1376 23.4496 24.1664-2.1504 49.0496-13.2096 59.6992-36.352 12.0832-26.112 4.4032-63.7952 3.584-91.648-0.4096-13.4144-2.9696-28.7744-0.8192-41.984 2.2528-13.9264 15.6672-15.872 27.9552-17.92 24.1664-4.096 56.6272-8.4992 78.4384 5.2224 23.04 14.4384 35.84 39.5264 61.5424 51.0976 23.9616 10.752 50.3808 10.9568 75.8784 6.656 92.16-15.5648 213.0944-128 143.0528-224.9728a123.67872 123.67872 0 0 0-59.6992-44.7488c-28.3648-9.9328-58.5728-5.12-87.7568-2.9696-21.4016 1.536-54.3744 3.2768-66.6624-18.7392-14.336-25.6 14.6432-42.1888 23.7568-62.8736 13.0048-29.4912-7.7824-51.4048-29.4912-68.9152-23.552-18.944-50.7904-34.304-82.0224-32.1536-32.6656 2.2528-58.88 22.2208-90.112 29.184-32.8704 7.3728-45.9776-15.872-41.984-45.568 1.7408-13.0048-12.288-23.8592-23.9616-23.9616-14.6432-0.4096-22.6304 10.9568-24.2688 23.7568zM629.4528 975.6672c-10.8544-29.0816-32.4608-45.8752-54.0672-66.7648-24.8832-24.1664-28.16-54.4768-19.3536-87.1424 8.3968-31.4368 25.7024-60.2112 49.152-82.7392 19.7632-18.8416 50.176-36.2496 70.656-9.8304 16.2816 20.992 26.9312 46.592 53.8624 56.1152 31.3344 11.1616 64.8192-4.608 89.7024-23.3472 48.5376-36.5568 85.6064-119.7056 153.8048-120.4224 30.8224-0.3072 30.9248-48.3328 0-48.0256-61.5424 0.6144-103.0144 45.6704-140.6976 88.6784-18.0224 20.5824-37.6832 43.7248-63.488 54.4768-28.5696 11.8784-36.2496-9.728-50.3808-29.7984-14.336-20.3776-32.0512-36.352-57.6512-39.3216-27.7504-3.2768-54.4768 9.0112-75.9808 25.6-44.6464 34.7136-75.1616 90.5216-80.896 146.7392-3.072 30.9248 3.584 62.1568 22.9376 86.8352 16.384 20.992 46.592 36.1472 56.1152 61.6448 10.752 28.672 57.2416 16.2816 46.2848-12.6976z\" p-id=\"23997\" fill=\"#ffffff\"><\/path><\/svg><\/span><\/p>\n\n\n\n<p class=\"gb-text gb-text-79caae51\">Commercializzazione globale<\/p>\n\n\n\n<p class=\"gb-text gb-text-7758423e\">Serviamo clienti e partner in oltre 80 paesi e regioni.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div>\n<div class=\"gb-element-2dea97ed\">\n<div>\n<p class=\"gb-text gb-text-6f6eaf18\">Fiducia di clienti provenienti da settori e continenti diversi<\/p>\n\n\n\n<h2 class=\"gb-text gb-text-27645bff\">Casi globali di trasformatori di potenza ad alta tensione Unicore<\/h2>\n\n\n\n<img decoding=\"async\" class=\"gb-media-cc28cdbe\" alt=\"\" title=\"2\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/2-1.png\"\/>\n\n\n\n<div class=\"gb-element-6d7b0fba\">\n<div class=\"gb-element-c609ea8f\">\n<div>\n<div class=\"gb-element-f9f7867c box-shadow\">\n<img decoding=\"async\" class=\"gb-media-bca5d4a3\" alt=\"\" title=\"trasformatore-alta-tensione-caso2\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/high-voltage-power-transformer-case-2.jpg\"\/>\n\n\n\n<div class=\"gb-element-1765c2d0\">\n<h3 class=\"gb-text gb-text-f740cbd8\">Trasformatore di potenza ad alta tensione per il Sudafrica<\/h3>\n\n\n\n<div class=\"gb-element-098c0b2c\">\n<div class=\"gb-element-a180c320\">\n<div>\n<p class=\"gb-text gb-text-48cd9c52\">Sottostazione primaria \u2013 Rete di trasmissione<\/p>\n<\/div>\n\n\n\n<div>\n<p class=\"gb-text gb-text-eb3d5632\">000 kVA<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div>\n<div class=\"gb-element-5bd8c640 box-shadow\">\n<img decoding=\"async\" class=\"gb-media-86ed707c\" alt=\"\" title=\"trasformatore-alta-tensione-caso1\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/high-voltage-power-transformer-case-1.jpg\"\/>\n\n\n\n<div class=\"gb-element-93dfcfd4\">\n<h3 class=\"gb-text gb-text-05c04d29\">Trasformatore di potenza ad alta tensione per il Marocco<\/h3>\n\n\n\n<div class=\"gb-element-6e05cfc6\">\n<div class=\"gb-element-37d5e212\">\n<div>\n<p class=\"gb-text gb-text-b2f9ac93\">Collegamento alla rete per energie rinnovabili \u2013 Impianto fotovoltaico<\/p>\n<\/div>\n\n\n\n<div>\n<p class=\"gb-text gb-text-5c5327b0\">000 kVA<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div>\n<div class=\"gb-element-8b59ba29 box-shadow\">\n<img decoding=\"async\" class=\"gb-media-d653120a\" alt=\"\" title=\"trasformatore-alta-tensione-caso3\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/high-voltage-power-transformer-case-3.jpg\"\/>\n\n\n\n<div class=\"gb-element-905c8221\">\n<h3 class=\"gb-text gb-text-79074710\">Trasformatore di potenza ad alta tensione per l\u2019Ecuador<\/h3>\n\n\n\n<div class=\"gb-element-f75c5e6b\">\n<div class=\"gb-element-e4deae8a\">\n<div>\n<p class=\"gb-text gb-text-16867385\">Prelevamento industriale di energia \u2013 Operazione mineraria<\/p>\n<\/div>\n\n\n\n<div>\n<p class=\"gb-text gb-text-cc654af2\">000 kVA<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div>\n<div class=\"gb-element-77245808\">\n<div>\n<div>\n<div class=\"gb-element-c0e4962c\">\n<div class=\"gb-element-9d54420c\">\n<p class=\"gb-text gb-text-c09c8a03\">UNICORE ELECTRIC<\/p>\n\n\n\n<p class=\"gb-text gb-text-50323bcd\">Soluzioni per trasformatori<\/p>\n<\/div>\n\n\n\n<img decoding=\"async\" class=\"gb-media-8ef7f3b5\" alt=\"\" title=\"ITAM_logo\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/05\/ITAM_logo-scaled.png\"\/>\n<\/div>\n\n\n\n<p class=\"gb-text gb-text-41d1b0ba\">Collaboriamo con i leader del settore per offrire eccellenza nelle soluzioni energetiche<\/p>\n\n\n\n<h2 class=\"gb-text gb-text-d257a3ad\">La nostra rete globale di partner<\/h2>\n\n\n\n<img decoding=\"async\" class=\"gb-media-d2671e62\" alt=\"\" title=\"2\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/2-1.png\"\/>\n\n\n\n<div class=\"gb-element-c8e1af54\">\n<div>\n<div class=\"gb-carousel gb-carousel-c21c0c88\" data-slides-per-view=\"10\" data-space-between=\"5px\" data-loop=\"true\" data-autoplay-enabled=\"true\" data-carousel-id=\"c21c0c88\">\n<div class=\"gb-carousel-items\">\n<div class=\"gb-carousel-item\">\n<img decoding=\"async\" class=\"gb-media-d2b2f5fd\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/10099.png\" alt=\"\" title=\"10099\"\/>\n<\/div>\n\n\n\n<div class=\"gb-carousel-item\">\n<img decoding=\"async\" class=\"gb-media-95efd3a0\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/10069.png\" alt=\"\" title=\"10069\"\/>\n<\/div>\n\n\n\n<div class=\"gb-carousel-item\">\n<img decoding=\"async\" class=\"gb-media-3ad45c00\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/10070.png\" alt=\"\" title=\"10070\"\/>\n<\/div>\n\n\n\n<div class=\"gb-carousel-item\">\n<img decoding=\"async\" class=\"gb-media-57c02df6\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/10086.png\" alt=\"\" title=\"10086\"\/>\n<\/div>\n\n\n\n<div class=\"gb-carousel-item\">\n<img decoding=\"async\" class=\"gb-media-bfabf40d\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/10068.png\" alt=\"\" title=\"10068\"\/>\n<\/div>\n\n\n\n<div class=\"gb-carousel-item\">\n<img decoding=\"async\" class=\"gb-media-2e0c10f7\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/10067.png\" alt=\"\" title=\"10067\"\/>\n<\/div>\n\n\n\n<div class=\"gb-carousel-item\">\n<img decoding=\"async\" class=\"gb-media-cf807e4d\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/10085.png\" alt=\"\" title=\"10085\"\/>\n<\/div>\n\n\n\n<div class=\"gb-carousel-item\">\n<img decoding=\"async\" class=\"gb-media-17b50744\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/10088.png\" alt=\"\" title=\"10088\"\/>\n<\/div>\n\n\n\n<div class=\"gb-carousel-item\">\n<img decoding=\"async\" class=\"gb-media-9a1e6f3e\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/10098.png\" alt=\"\" title=\"10098\"\/>\n<\/div>\n\n\n\n<div class=\"gb-carousel-item\">\n<img decoding=\"async\" class=\"gb-media-19a37092\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/10097.png\" alt=\"\" title=\"10097\"\/>\n<\/div>\n\n\n\n<div class=\"gb-carousel-item\">\n<img decoding=\"async\" class=\"gb-media-5ea364cd\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/10071.png\" alt=\"\" title=\"10071\"\/>\n<\/div>\n\n\n\n<div class=\"gb-carousel-item\">\n<img decoding=\"async\" class=\"gb-media-fea05aec\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/10087.png\" alt=\"\" title=\"10087\"\/>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"gb-element-d5e7c89b\">\n<a class=\"gb-text gb-text-9715a9c1\" href=\"#popmake-128\">Personalizza le tue soluzioni per trasformatori<\/a>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"gb-element-8fb06003\">\n<div class=\"gb-element-cc2bbf88\">\n<div>\n<div class=\"gb-element-4d156d64\">\n<p class=\"gb-text gb-text-210a0b65\">Esperienze reali di professionisti del settore dei trasformatori che ripongono fiducia in Unicore<\/p>\n\n\n\n<h2 class=\"gb-text gb-text-883c59e5\">Cosa dicono i nostri clienti<\/h2>\n\n\n\n<img decoding=\"async\" class=\"gb-media-e8c56f4e\" alt=\"\" title=\"2\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/2-1.png\"\/>\n\n\n\n<div class=\"gb-element-d20c9598\">\n<div class=\"gb-element-87b61983\">\n<div>\n<div class=\"gb-element-1e84310d\">\n<p class=\"gb-text gb-text-19f2dd29\">Prestazioni eccellenti per la nostra rete di trasmissione<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u201cAbbiamo specificato il trasformatore di potenza ad alta tensione da 110 kV di Unicore per un intervento critico di potenziamento della sottostazione primaria. La progettazione elettromagnetica ha fornito esattamente le prestazioni a basse perdite richieste dal nostro gestore di rete.\u201d<\/p>\n\n\n\n<div class=\"gb-element-2139ff52\">\n<div class=\"gb-element-d21568f7\">\n<figure class=\"wp-block-image size-full is-resized is-style-rounded\"><img decoding=\"async\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/high-voltage-power-transformer-feedback-1.jpg\" alt=\"\" class=\"wp-image-1011\" style=\"width:auto;height:50px\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"gb-element-b9981728\">\n<p class=\"gb-text gb-text-9ca376c2\">Ibrahim Al-Farsi<\/p>\n\n\n\n<p class=\"gb-text gb-text-dea6f2f9\">Arabia Saudita<\/p>\n<\/div>\n\n\n\n<div>\n<p class=\"wp-block-paragraph\">\u2b50\u2b50\u2b50\u2b50\u2b50<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div>\n<div class=\"gb-element-53402347\">\n<p class=\"gb-text gb-text-c508d4b6\">Perfetta capacit\u00e0 di resistenza al cortocircuito<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u201cOperando in un ambiente industriale caratterizzato da frequenti eventi di guasto, la capacit\u00e0 di resistenza al cortocircuito era il nostro criterio principale di selezione. Il trasformatore ad alta tensione Unicore \u00e8 ora in servizio da tre anni e ha superato numerosi incidenti di cortocircuito senza presentare alcun problema strutturale o isolante.\u201d<\/p>\n\n\n\n<div class=\"gb-element-1e0e7256\">\n<div class=\"gb-element-8bef609d\">\n<figure class=\"wp-block-image size-full is-resized is-style-rounded\"><img decoding=\"async\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/high-voltage-power-transformer-feedback-2.jpg\" alt=\"\" class=\"wp-image-1012\" style=\"width:auto;height:50px\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"gb-element-07d1ac19\">\n<p class=\"gb-text gb-text-83906a23\">Sofia Andrade<\/p>\n\n\n\n<p class=\"gb-text gb-text-4bb9c85d\">Cile<\/p>\n<\/div>\n\n\n\n<div>\n<p class=\"wp-block-paragraph\">\u2b50\u2b50\u2b50\u2b50\u2b50<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"gb-element-77ed37a3\">\n<a class=\"gb-text gb-text-0836ac18\" href=\"#popmake-128\">Contattate subito i nostri esperti<\/a>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div>\n<div class=\"gb-element-1f54adec\">\n<p class=\"gb-text gb-text-8408f40a\">Esplorate configurazioni di ingegneria di precisione progettate per una stabilit\u00e0 di rete superiore<\/p>\n\n\n\n<h2 class=\"gb-text gb-text-31380b0f\">Eccellenza tecnica e specifiche di produzione<\/h2>\n\n\n\n<img decoding=\"async\" class=\"gb-media-27d9cffc\" alt=\"\" title=\"2\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/2-1.png\"\/>\n\n\n\n<div class=\"gb-element-bf05250a\">\n<div class=\"gb-element-703978a8\">\n<div class=\"gb-element-0275867d\">\n<h3 class=\"gb-text gb-text-e8145769\">Architettura del nucleo ad alta permeabilit\u00e0<\/h3>\n\n\n\n<p class=\"gb-text gb-text-2bfe29ce\">UNICORE utilizza acciaio al silicio orientato in grani di prima qualit\u00e0 con un particolare giunto a gradini. Questa ingegneria di precisione consente una riduzione delle perdite a vuoto pari a 30% e livelli di rumore inferiori a 65 dB, garantendo un\u2019alta efficienza e un funzionamento silenzioso per le moderne reti urbane di trasmissione e distribuzione dell\u2019energia.<\/p>\n\n\n\n<div class=\"gb-element-c9ab7717\">\n<div>\n<p class=\"gb-text gb-text-f1c0d84d\">Perdite a vuoto ridotte del 30%<\/p>\n<\/div>\n\n\n\n<div>\n<p class=\"gb-text gb-text-7305dde8\">inferiore a 65 dB<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"gb-element-420d162c\">\n<h3 class=\"gb-text gb-text-1c942745\">Tecnologia avanzata di isolamento sotto vuoto<\/h3>\n\n\n\n<p class=\"gb-text gb-text-f9183fd3\">Integrando cartone pressato di prima qualit\u00e0 con olio minerale degassato sotto vuoto, otteniamo livelli di scarica parziale inferiori a 10 pC. Questo isolamento di elevata qualit\u00e0 previene l\u2019invecchiamento termico ed estende efficacemente la vita operativa del trasformatore a oltre 30 anni anche negli ambienti pi\u00f9 estremi del mondo.<\/p>\n\n\n\n<div class=\"gb-element-80480585\">\n<div>\n<p class=\"gb-text gb-text-d4d12c04\">Livello di scarica parziale &lt;10 pC<\/p>\n<\/div>\n\n\n\n<div>\n<p class=\"gb-text gb-text-3af80bfb\">Vita utile superiore ai 30 anni<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"gb-element-deb3cd32\">\n<h3 class=\"gb-text gb-text-ca7c22e9\">Sistemi di avvolgimento in rame ad alta purezza<\/h3>\n\n\n\n<p class=\"gb-text gb-text-d5a8b47d\">Le nostre bobine sono realizzate in rame ossigeno-free al 99.9%, trattato mediante una tecnologia specializzata di essiccazione sotto vuoto. Questa progettazione garantisce la rigidit\u00e0 meccanica necessaria per resistere alle forze di cortocircuito fino a 20 volte la corrente nominale, assicurando la massima sicurezza e affidabilit\u00e0 della rete anche in scenari di guasto estremi.<\/p>\n\n\n\n<div class=\"gb-element-6e2910fe\">\n<div>\n<p class=\"gb-text gb-text-f454f8ec\">Rame puro al 99.9%<\/p>\n<\/div>\n\n\n\n<div>\n<p class=\"gb-text gb-text-e8b6c3ad\">Resistenza fino a 20 volte la corrente nominale<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"gb-element-acce8952\">\n<h3 class=\"gb-text gb-text-1b66da17\">Regolazione di tensione di precisione integrata<\/h3>\n\n\n\n<p class=\"gb-text gb-text-03c609be\">Dotato di regolatori di presa sotto carico di alta precisione, UNICORE offre un campo di regolazione standard pari a \u00b18 \u00d7 1.25%. Questo sistema consente un aggiustamento continuo e in tempo reale della tensione per compensare le fluttuazioni di rete, garantendo una fornitura di energia stabile senza alcuna interruzione per apparecchiature sensibili.<\/p>\n\n\n\n<div class=\"gb-element-f8fbf9f6\">\n<div>\n<p class=\"gb-text gb-text-7aa651e1\">Gamma di \u00b18\u00d71,251 TP3T<\/p>\n<\/div>\n\n\n\n<div>\n<p class=\"gb-text gb-text-a4565f28\">Controllo senza interruzioni<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"gb-element-ec9bbc02\">\n<a class=\"gb-text gb-text-e82e9fe6\" href=\"#popmake-128\">Consulta i nostri esperti<\/a>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div>\n<div class=\"gb-element-1c9dad2e\">\n<p class=\"gb-text gb-text-89b37b79\">Approfondimenti ingegneristici sui costi<\/p>\n\n\n\n<h2 class=\"gb-text gb-text-5d78811c\">Quali fattori determinano il costo di un trasformatore ad alta tensione?<\/h2>\n\n\n\n<img decoding=\"async\" class=\"gb-media-05e98422\" alt=\"\" title=\"2\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/2-1.png\"\/>\n\n\n\n<div class=\"gb-element-f06a240a\">\n<p class=\"gb-text gb-text-234bb0b7\"><strong>1. <strong>Materiale del conduttore (rame vs. alluminio)<\/strong><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Il materiale scelto per gli avvolgimenti influisce direttamente sul prezzo d\u2019acquisto iniziale. Sebbene offriamo opzioni in alluminio economiche, specifichiamo tipicamente rame puro per reti ad alte prestazioni.&nbsp;<strong>Il rame garantisce al vostro sistema una superiore conducibilit\u00e0 elettrica, un migliore smaltimento del calore e una maggiore durata nel tempo.<\/strong>&nbsp;Il costo pi\u00f9 elevato iniziale dei materiali \u00e8 naturalmente bilanciato dai risparmi energetici e di manutenzione che otterrete nel tempo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Produzione di precisione e costi del lavoro<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Non possiamo automatizzare completamente la produzione degli avvolgimenti ad alta tensione. Per garantire un\u2019assoluta integrit\u00e0 dell\u2019isolamento, il montaggio degli avvolgimenti richiede&nbsp;<strong>un avvolgimento manuale preciso eseguito da tecnici esperti.<\/strong>&nbsp;Questo processo artigianale aumenta i tempi di produzione e i costi base, ma \u00e8 essenziale per prevenire danni microscopici all\u2019isolamento e assicurare che il trasformatore resista a severi stress elettrici.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Componenti isolanti di alta qualit\u00e0<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Poich\u00e9 il vostro equipaggiamento opera ad alta tensione, necessita di un sistema isolante interno robusto. Durante la produzione, utilizziamo&nbsp;<strong>nastri isolanti elettrici di prima qualit\u00e0 e presspan ad alta densit\u00e0<\/strong>&nbsp;per fissare saldamente gli avvolgimenti. L\u2019elevato quantitativo di questi materiali specializzati incrementa il costo, ma sono fondamentali per prevenire cortocircuiti interni ed estendere il ciclo di vita dell\u2019equipaggiamento.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Diametro del filo e specifiche fisiche<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dimensioniamo le dimensioni fisiche dei conduttori interni in base alle vostre specifiche esigenze di carico. Se il vostro progetto richiede correnti pi\u00f9 elevate o una riduzione delle perdite termiche (I\u00b2R), progetteremo l\u2019unit\u00e0 utilizzando&nbsp;<strong>conduttori con diametro del filo maggiore.<\/strong>&nbsp;Un filo pi\u00f9 spesso richiede un consumo significativamente maggiore di rame o alluminio grezzo, il che modifica il prezzo per riflettere il volume personalizzato di materiale e il livello superiore di efficienza.<\/p>\n<\/div>\n\n\n\n<div class=\"gb-element-da47c1e5\">\n<a class=\"gb-text gb-text-a92b9091\" href=\"#popmake-128\">Richiedi un preventivo gratuito<\/a>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div>\n<div class=\"gb-element-7005fe72\">\n<p class=\"gb-text gb-text-451a788c\">Navigare tra le classificazioni di tensione<\/p>\n\n\n\n<h2 class=\"gb-text gb-text-2f4f912c\">Quale livello di tensione richiede il vostro progetto?<\/h2>\n\n\n\n<img decoding=\"async\" class=\"gb-media-f8a26996\" alt=\"\" title=\"2\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/2-1.png\"\/>\n\n\n\n<div class=\"gb-element-832e6e20\">\n<p class=\"gb-text-baac51aa\"><span class=\"gb-shape\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M440 6.5L24 246.4c-34.4 19.9-31.1 70.8 5.7 85.9L144 379.6V464c0 46.4 59.2 65.5 86.6 28.6l43.8-59.1 111.9 46.2c5.9 2.4 12.1 3.6 18.3 3.6 8.2 0 16.3-2.1 23.6-6.2 12.8-7.2 21.6-20 23.9-34.5l59.4-387.2c6.1-40.1-36.9-68.8-71.5-48.9zM192 464v-64.6l36.6 15.1L192 464zm212.6-28.7l-153.8-63.5L391 169.5c10.7-15.5-9.5-33.5-23.7-21.2L155.8 332.6 48 288 464 48l-59.4 387.3z\"><\/path><\/svg><\/span><span class=\"gb-text\">Distribuzione a bassa tensione (&lt; 1 kV)<\/span><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Operando sotto i 1.000 volt, la bassa tensione rappresenta l\u2019ultima fase della distribuzione dell\u2019energia. Quando progettiamo sistemi di distribuzione per ambienti commerciali o residenziali, riduciamo specificamente la tensione per&nbsp;<strong>prioritizzare la sicurezza delle persone.<\/strong>&nbsp;Questo livello viene utilizzato direttamente per la distribuzione standard negli edifici e per l\u2019illuminazione, poich\u00e9&nbsp;<strong>alimenta direttamente gli apparecchi finali<\/strong>&nbsp;senza necessit\u00e0 di ulteriori trasformazioni su larga scala.<\/p>\n\n\n\n<p class=\"gb-text-83e1d34c\"><span class=\"gb-shape\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M440 6.5L24 246.4c-34.4 19.9-31.1 70.8 5.7 85.9L144 379.6V464c0 46.4 59.2 65.5 86.6 28.6l43.8-59.1 111.9 46.2c5.9 2.4 12.1 3.6 18.3 3.6 8.2 0 16.3-2.1 23.6-6.2 12.8-7.2 21.6-20 23.9-34.5l59.4-387.2c6.1-40.1-36.9-68.8-71.5-48.9zM192 464v-64.6l36.6 15.1L192 464zm212.6-28.7l-153.8-63.5L391 169.5c10.7-15.5-9.5-33.5-23.7-21.2L155.8 332.6 48 288 464 48l-59.4 387.3z\"><\/path><\/svg><\/span><span class=\"gb-text\">Reti a media tensione (1 kV \u2013 35 kV)<\/span><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Con un intervallo compreso tra 1 kV e 35 kV, la media tensione gestisce la distribuzione locale dell\u2019energia. Se gestite una stazione di trasformazione urbana, un grande impianto manifatturiero o un\u2019infrastruttura mineraria, la vostra rete dipende da questo livello. Utilizziamo la capacit\u00e0 a media tensione per&nbsp;<strong>azionare macchinari industriali pesanti e alimentare grandi complessi commerciali<\/strong>, soddisfacendo domande energetiche locali molto superiori a quelle supportabili da una rete residenziale standard.<\/p>\n\n\n\n<p class=\"gb-text-1618b27d\"><span class=\"gb-shape\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M440 6.5L24 246.4c-34.4 19.9-31.1 70.8 5.7 85.9L144 379.6V464c0 46.4 59.2 65.5 86.6 28.6l43.8-59.1 111.9 46.2c5.9 2.4 12.1 3.6 18.3 3.6 8.2 0 16.3-2.1 23.6-6.2 12.8-7.2 21.6-20 23.9-34.5l59.4-387.2c6.1-40.1-36.9-68.8-71.5-48.9zM192 464v-64.6l36.6 15.1L192 464zm212.6-28.7l-153.8-63.5L391 169.5c10.7-15.5-9.5-33.5-23.7-21.2L155.8 332.6 48 288 464 48l-59.4 387.3z\"><\/path><\/svg><\/span><span class=\"gb-text\">Trasmissione ad alta tensione (35 kV \u2013 230 kV)<\/span><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Con un intervallo compreso tra 35 kV e 230 kV, l\u2019alta tensione viene utilizzata esclusivamente per il trasporto su larga scala di energia proveniente da centrali di generazione. Se il vostro progetto prevede&nbsp;<strong>trasmissione su lunga distanza nella rete<\/strong>, questo \u00e8 il livello operativo di cui avete bisogno. Incrementando esponenzialmente la tensione, contribuiamo a ridurre proporzionalmente la corrente elettrica \u2014 l\u2019unico meccanismo fisico efficace per&nbsp;<strong>minimizzare le perdite di energia termica (perdite I\u00b2R)<\/strong>&nbsp;durante il trasporto di corrente alternata attraverso le vostre reti regionali.<\/p>\n\n\n\n<p class=\"gb-text-776cdebd\"><span class=\"gb-shape\"><svg aria-hidden=\"true\" role=\"img\" height=\"1em\" width=\"1em\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path fill=\"currentColor\" d=\"M440 6.5L24 246.4c-34.4 19.9-31.1 70.8 5.7 85.9L144 379.6V464c0 46.4 59.2 65.5 86.6 28.6l43.8-59.1 111.9 46.2c5.9 2.4 12.1 3.6 18.3 3.6 8.2 0 16.3-2.1 23.6-6.2 12.8-7.2 21.6-20 23.9-34.5l59.4-387.2c6.1-40.1-36.9-68.8-71.5-48.9zM192 464v-64.6l36.6 15.1L192 464zm212.6-28.7l-153.8-63.5L391 169.5c10.7-15.5-9.5-33.5-23.7-21.2L155.8 332.6 48 288 464 48l-59.4 387.3z\"><\/path><\/svg><\/span><span class=\"gb-text\">Tensione extra e ultra-alta (\u2265 230 kV)<\/span><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La tensione extra-alta (230 kV\u20131.000 kV) e la tensione ultra-alta (\u2265 1.000 kV) gestiscono i livelli pi\u00f9 elevati assoluti di distribuzione dell\u2019energia. Avrete bisogno di questi livelli quando gestite&nbsp;<strong>reti dorsali interregionali<\/strong>. Progettiamo sistemi su questa scala estrema per consentirvi di trasportare&nbsp;<strong>capacit\u00e0 elettrica su vasta scala transnazionale<\/strong>&nbsp;direttamente dalle stazioni di generazione remote di grandi dimensioni ai principali centri di distribuzione regionale.<\/p>\n<\/div>\n\n\n\n<div class=\"gb-element-6d8bdcba\">\n<a class=\"gb-text gb-text-0c97bc0e\" href=\"#popmake-128\">Richiedi un preventivo gratuito<\/a>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div>\n<div class=\"gb-element-fbfbd41d\">\n<p class=\"gb-text gb-text-dc1e8bfb\">Garantire stabilit\u00e0 ad alta tensione per settori energetici globali critici<\/p>\n\n\n\n<h2 class=\"gb-text gb-text-77a0a0f3\">Applicazioni dei trasformatori ad alta tensione e soluzioni settoriali<\/h2>\n\n\n\n<img decoding=\"async\" class=\"gb-media-11e773f9\" alt=\"\" title=\"2\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/2-1.png\"\/>\n\n\n\n<div class=\"gb-element-71eb9578\">\n<div class=\"gb-element-337e823e\">\n<div class=\"gb-element-755aac83\">\n<h3 class=\"gb-text gb-text-3899801d\">Alimentazione delle stazioni di trasformazione delle reti di pubblica utilit\u00e0<\/h3>\n\n\n\n<p class=\"gb-text gb-text-1afa3f91\">I trasformatori UNICORE costituiscono il collegamento critico nelle reti nazionali e regionali di trasmissione. Progettati per un\u2019estrema affidabilit\u00e0, stabilizzano il flusso di energia su lunga distanza e assicurano una distribuzione efficiente all\u2019energia verso centri urbani e reti residenziali, con perdite di trasmissione minime e massima stabilit\u00e0.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Gamma 66 kV \u2013 220 kV<\/li>\n\n\n\n<li>Progettazione pronta per la rete<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"gb-element-661bd806\">\n<h3 class=\"gb-text gb-text-f55626d5\">Impianti di energia rinnovabile<\/h3>\n\n\n\n<p class=\"gb-text gb-text-dbbe4747\">Ottimizzati per parchi fotovoltaici su larga scala e parchi eolici, le unit\u00e0 UNICORE GSU gestiscono carichi variabili e sollecitazioni armoniche. I nostri trasformatori facilitano un\u2019efficace immissione in rete, massimizzando il costo livellato dell\u2019elettricit\u00e0 per gli sviluppatori di energia rinnovabile in climi diversi.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Ottimizzato per armoniche<\/li>\n\n\n\n<li>Innalzamento a basse perdite<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"gb-element-e1af1b30\">\n<h3 class=\"gb-text gb-text-3e717e86\">Complessi industriali pesanti<\/h3>\n\n\n\n<p class=\"gb-text gb-text-913d1512\">Fornendo potenza ad alta capacit\u00e0 per acciaierie, operazioni minerarie e complessi petrochimici, le unit\u00e0 UNICORE resistono a cicli operativi intensivi. Garantiamo un\u2019erogazione continua di elettricit\u00e0 24\/7 per prevenire costose interruzioni in ambienti industriali ad alta intensit\u00e0 energetica e severi.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Elevato fattore di carico<\/li>\n\n\n\n<li>Operativit\u00e0 24\/7<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"gb-element-f025a879\">\n<h3 class=\"gb-text gb-text-e5dda069\">Infrastrutture pubbliche critiche<\/h3>\n\n\n\n<p class=\"gb-text gb-text-f121f81b\">Supportando ferrovie ad alta velocit\u00e0, aeroporti internazionali e data center di grandi dimensioni, i nostri trasformatori forniscono il controllo preciso della tensione richiesto per gli hub tecnologici moderni. Sono progettati per soddisfare le elevate esigenze di disponibilit\u00e0 delle infrastrutture pubbliche e digitali critiche per la missione.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Regolazione precisa<\/li>\n\n\n\n<li>Elevata disponibilit\u00e0<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"gb-element-50dfb073\">\n<a class=\"gb-text gb-text-b225c595\" href=\"#popmake-128\">Richiedi un preventivo gratuito<\/a>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div>\n<div class=\"gb-element-7091a687\">\n<p class=\"gb-text gb-text-b4a5cdc3\">Garantire prestazioni operative ottimali mediante rigorosa verifica in laboratorio<\/p>\n\n\n\n<h2 class=\"gb-text gb-text-425225f5\">Standard internazionali di conformit\u00e0 UNICORE<\/h2>\n\n\n\n<img decoding=\"async\" class=\"gb-media-5bcf0dbc\" alt=\"\" title=\"2\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/2-1.png\"\/>\n\n\n\n<div class=\"gb-element-18e255ab\">\n<p class=\"wp-block-paragraph\">Dopo una verifica di fabbrica riuscita, gestiamo le fasi critiche dell\u2019esecuzione del progetto per garantirne il successo operativo. Il nostro team coordina logistica specializzata per carichi pesanti e fornisce una completa assistenza tecnica in loco, dall\u2019assemblaggio strutturale all\u2019energizzazione finale. Questo modello di servizio integrato riduce al minimo i rischi di installazione e garantisce che ogni unit\u00e0 ad alta tensione sia ottimizzata per le specifiche esigenze del vostro ambiente di rete.<\/p>\n\n\n\n<div class=\"gb-element-e684a4d0\">\n<div class=\"gb-element-3801ed11\">\n<img loading=\"lazy\" decoding=\"async\" width=\"1400\" height=\"1000\" class=\"gb-media-1c377327\" alt=\"\" title=\"Trasformatori-Alta-Tensione-Esportati-in-Myanmar\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/High-Voltage-Power-Transformers-Exported-to-Myanmar.webp\" srcset=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/High-Voltage-Power-Transformers-Exported-to-Myanmar.webp 1400w, https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/High-Voltage-Power-Transformers-Exported-to-Myanmar-300x214.webp 300w, https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/High-Voltage-Power-Transformers-Exported-to-Myanmar-1024x731.webp 1024w, https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/High-Voltage-Power-Transformers-Exported-to-Myanmar-768x549.webp 768w\" sizes=\"auto, (max-width: 1400px) 100vw, 1400px\" \/>\n<\/div>\n\n\n\n<div class=\"gb-element-b408822e\">\n<p class=\"gb-text-162e1846\"><span class=\"gb-shape\"><svg t=\"1783586745239\" class=\"icon\" viewbox=\"0 0 1024 1024\" version=\"1.1\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" p-id=\"2573\" width=\"200\" height=\"200\"><path d=\"M496 0C222.048 0 0 222.048 0 496s222.048 496 496 496 496-222.048 496-496S769.952 0 496 0z m431.2 480H735.328c-1.76-70.88-14.368-138.592-36.736-200.576 43.2-18.016 83.136-41.984 119.552-70.304C882.88 281.792 923.36 376.16 927.2 480zM478.304 927.104c-53.184-44.288-97.792-101.792-130.432-168.576C389.76 745.44 434.144 738.272 480 736.8v190.368c-0.576 0-1.12-0.032-1.696-0.064z m35.328-862.208c60.352 50.24 109.6 117.536 142.912 196.032-45.632 15.584-94.112 24.64-144.576 26.24V64.8c0.608 0.032 1.12 0.064 1.664 0.096z m53.312 5.44c88.32 14.688 167.552 55.936 229.248 115.648-33.504 25.696-70.112 47.456-109.696 63.936-29.12-69.024-69.984-130.048-119.552-179.584zM480 64.8v222.368c-50.464-1.632-98.976-10.656-144.576-26.24 33.312-78.496 82.56-145.792 142.912-196.032 0.576-0.032 1.088-0.064 1.664-0.096zM305.472 249.952c-39.52-16.48-76.16-38.24-109.664-63.936 61.664-59.712 140.928-100.96 229.248-115.648-49.6 49.504-90.432 110.528-119.584 179.584z m17.888 40.48c49.344 17.12 101.92 27.104 156.64 28.768V480H288.672c1.728-67.008 13.6-131.04 34.688-189.568zM480 512v192.8c-50.464 1.536-99.264 9.792-145.248 24.608C307.04 663.424 290.688 589.92 288.672 512H480z m-54.944 409.664C345.92 908.512 274.048 874.048 215.616 824c31.52-21.856 65.6-40.352 102.016-54.4 27.904 57.856 64.416 109.216 107.424 152.064zM512 927.2V736.832c45.824 1.472 90.24 8.64 132.128 21.728-32.672 66.784-77.248 124.288-130.432 168.576-0.544 0-1.12 0.032-1.696 0.064z m162.368-157.6c36.384 14.048 70.432 32.576 102.016 54.4-58.432 50.016-130.304 84.512-209.44 97.664 43.008-42.848 79.488-94.208 107.424-152.064z m-17.12-40.192C611.232 714.592 562.432 706.336 512 704.8V512h191.328c-2.016 77.92-18.4 151.424-46.08 217.408zM512 480V319.2c54.688-1.664 107.264-11.616 156.64-28.736 21.056 58.528 32.928 122.56 34.688 189.568H512zM173.888 209.12c36.416 28.32 76.352 52.288 119.52 70.304C271.04 341.408 258.432 409.12 256.672 480H64.8c3.84-103.84 44.32-198.208 109.088-270.88zM64.8 512h191.872c1.984 81.76 19.072 158.976 48.096 228.384-40.544 15.808-78.336 36.864-113.216 61.792C116.416 727.392 68.992 625.152 64.8 512z m735.648 290.144c-34.88-24.896-72.672-45.984-113.248-61.792 29.056-69.408 46.112-146.624 48.128-228.384H927.2c-4.192 113.184-51.648 215.424-126.752 290.176z\" p-id=\"2574\" fill=\"#0a3aa3\"><\/path><\/svg><\/span><span class=\"gb-text\"><strong>Allineamento con standard internazionali<\/strong><\/span><\/p>\n\n\n\n<p class=\"gb-text gb-text-70d6e2fa\">Ogni unit\u00e0 UNICORE \u00e8 conforme agli standard IEC 60076 e IEEE\/ANSI C57. Ci\u00f2 garantisce piena compatibilit\u00e0 con la rete e prestazioni affidabili per progetti globali di infrastrutture elettriche per utility e industria.<\/p>\n\n\n\n<p class=\"gb-text-992f3a1d\"><span class=\"gb-shape\"><svg t=\"1783587297150\" class=\"icon\" viewbox=\"0 0 1024 1024\" version=\"1.1\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" p-id=\"3867\" width=\"200\" height=\"200\"><path d=\"M199.111111 1024c-62.577778 0-113.777778-51.2-113.777778-113.777778V227.555556c0-62.577778 51.2-113.777778 113.777778-113.777778 19.911111 0 36.977778 17.066667 36.977778 36.977778v54.044444c-42.666667 11.377778-73.955556 25.6-73.955556 71.111111V853.333333c0 51.2 39.822222 93.866667 93.866667 93.866667h497.777778c51.2 0 93.866667-42.666667 93.866666-93.866667V275.911111c0-45.511111-31.288889-59.733333-76.8-68.266667V153.6c-2.844444-22.755556 14.222222-39.822222 34.133334-39.822222 62.577778 0 113.777778 51.2 113.777778 113.777778v682.666666c0 62.577778-51.2 113.777778-113.777778 113.777778H199.111111z m341.333333-304.355556h227.555556c19.911111 0 36.977778 17.066667 36.977778 36.977778S787.911111 796.444444 768 796.444444h-227.555556c-19.911111 0-36.977778-17.066667-36.977777-36.977777s17.066667-39.822222 36.977777-39.822223z m0-301.511111h227.555556c19.911111 0 36.977778 17.066667 36.977778 36.977778s-17.066667 36.977778-36.977778 36.977778h-227.555556c-19.911111 0-36.977778-17.066667-36.977777-36.977778s17.066667-36.977778 36.977777-36.977778z m-227.555555-227.555555V150.755556c0-19.911111 17.066667-36.977778 36.977778-36.977778h36.977777c0-62.577778 51.2-113.777778 113.777778-113.777778s113.777778 51.2 113.777778 113.777778H654.222222c19.911111 0 36.977778 17.066667 36.977778 36.977778v36.977777L312.888889 190.577778z m-99.555556 233.244444c5.688889-5.688889 17.066667-5.688889 25.6 0l62.577778 62.577778 136.533333-136.533333c8.533333-8.533333 22.755556-8.533333 28.444445 0 8.533333 8.533333 8.533333 19.911111 0 28.444444l-147.911111 147.911111c-5.688889 2.844444-11.377778 5.688889-17.066667 5.688889-5.688889 0-8.533333-2.844444-11.377778-5.688889l-73.955555-73.955555c-11.377778-11.377778-11.377778-22.755556-2.844445-28.444445z m207.644445 403.911111c-8.533333 8.533333-22.755556 8.533333-28.444445 0L332.8 768l-59.733333 59.733333c-8.533333 8.533333-22.755556 8.533333-28.444445 0-8.533333-8.533333-8.533333-22.755556 0-28.444444l59.733334-59.733333-59.733334-59.733334c-8.533333-8.533333-8.533333-22.755556 0-28.444444 8.533333-8.533333 19.911111-8.533333 28.444445 0l59.733333 59.733333 59.733333-59.733333c8.533333-8.533333 22.755556-8.533333 28.444445 0 8.533333 8.533333 8.533333 19.911111 0 28.444444L361.244444 739.555556l59.733334 59.733333c8.533333 5.688889 8.533333 19.911111 0 28.444444z\" fill=\"#0a3aa3\" p-id=\"3868\"><\/path><\/svg><\/span><span class=\"gb-text\"><strong>Protocollo di prova di routine 100%<\/strong><\/span><\/p>\n\n\n\n<p class=\"gb-text gb-text-64e9e1e4\">Eseguiamo prove di routine 100%, che coprono la resistenza degli avvolgimenti, il rapporto di trasformazione e lo spostamento di fase. Questa validazione obbligatoria garantisce consegne prive di difetti ed elimina i rischi di messa in servizio per gli appaltatori internazionali.<\/p>\n\n\n\n<p class=\"gb-text-7f489e49\"><span class=\"gb-shape\"><svg t=\"1783587475081\" class=\"icon\" viewbox=\"0 0 1024 1024\" version=\"1.1\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" p-id=\"5031\" width=\"200\" height=\"200\"><path d=\"M942.545455 977.454545H81.454545a34.909091 34.909091 0 0 1-34.90909-34.90909V81.454545a34.909091 34.909091 0 0 1 69.818181 0V907.636364h826.181819a34.909091 34.909091 0 0 1 0 69.818181zM377.390545 743.284364a35.002182 35.002182 0 0 0 27.927273-23.179637l58.228364-169.472 133.259636-71.074909 90.251637 113.989818a34.909091 34.909091 0 0 0 58.321454-5.538909l216.622546-416.256a34.955636 34.955636 0 0 0-61.905455-32.256l-191.767273 368.453818-74.891636-94.626909a34.909091 34.909091 0 0 0-43.752727-9.122909l-171.101091 91.229091a34.909091 34.909091 0 0 0-16.570182 19.456l-40.820364 118.784-108.823272-150.667636a34.909091 34.909091 0 0 0-56.599273 40.866909l148.247273 205.265454a35.002182 35.002182 0 0 0 33.37309 14.149819z\" fill=\"#0a3aa3\" p-id=\"5032\"><\/path><\/svg><\/span><span class=\"gb-text\"><strong>Prove di tipo avanzate e speciali<\/strong><\/span><\/p>\n\n\n\n<p class=\"gb-text gb-text-28f6c9cc\">Laboratori avanzati eseguono prove di sovratensione da fulmine (1,2\/50 \u03bcs) e prove di innalzamento termico a pieno carico. Queste simulazioni verificano l\u2019integrit\u00e0 strutturale contro le sovratensioni da scarica e assicurano stabilit\u00e0 termica durante il funzionamento continuo.<\/p>\n\n\n\n<p class=\"gb-text-53edeab0\"><span class=\"gb-shape\"><svg t=\"1783587502203\" class=\"icon\" viewbox=\"0 0 1104 1024\" version=\"1.1\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" p-id=\"6102\" width=\"200\" height=\"200\"><path d=\"M1010.34 807.281L627.513 109.219c-14.088-25.677-35.883-40.387-59.811-40.387-23.919 0-45.743 14.709-59.822 40.366L352.372 392.085H176.515a65.25 65.25 0 0 0-65.057 65.057v390.342a65.25 65.25 0 0 0 65.057 65.057h390.342a64.722 64.722 0 0 0 6.76-0.356 31.675 31.675 0 0 0 4.422 0.305h370.013c28.838 0 52.442-11.923 64.752-32.711s11.405-47.207-2.46-72.498zM176.627 457.142h390.119l0.112 0.112v99.506H176.515v-99.506a1.159 1.159 0 0 1 0.112-0.112z m-0.112 164.676h390.342v65.057H176.515z m0 225.555v-95.441h390.342v95.441l-0.112 0.112H176.627z m771.537 0.112H631.915V457.143a65.25 65.25 0 0 0-65.057-65.057h-140.28l138.298-251.588a34.745 34.745 0 0 1 2.795-4.361 35.517 35.517 0 0 1 2.796 4.36l382.84 698.074a24.488 24.488 0 0 1 2.97 7.746 24.6 24.6 0 0 1-8.225 1.169z\" p-id=\"6103\" fill=\"#0a3aa3\"><\/path><\/svg><\/span><span class=\"gb-text\"><strong>Controllo qualit\u00e0 delle materie prime<\/strong><\/span><\/p>\n\n\n\n<p class=\"gb-text gb-text-77758de3\">I materiali subiscono analisi spettrali e test sull\u2019umidit\u00e0 prima dell\u2019assemblaggio. Manteniamo l\u2019olio isolante con umidit\u00e0 inferiore a 10 ppm e contenuto gassoso pari a 0,5% per garantire la massima stabilit\u00e0 dielettrica dell\u2019isolamento.<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"gb-element-c0d00b7c\">\n<a class=\"gb-text gb-text-288797a5\" href=\"#popmake-128\">Richiedi un preventivo gratuito<\/a>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div>\n<div class=\"gb-element-4fed5ab3\">\n<p class=\"gb-text gb-text-e2566f42\">Fondamenti delle attrezzature per la trasmissione di rete<\/p>\n\n\n\n<h2 class=\"gb-text gb-text-9d12bbec\">Comprendere i trasformatori di potenza ad alta tensione: meccanismi e funzioni fondamentali<\/h2>\n\n\n\n<img decoding=\"async\" class=\"gb-media-41193c42\" alt=\"\" title=\"2\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/2-1.png\"\/>\n\n\n\n<div class=\"gb-element-ca14d705\">\n<p class=\"wp-block-paragraph\"><strong>Definizione e ambito dell\u2019attrezzatura<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Un trasformatore di potenza ad alta tensione \u00e8 un\u2019apparecchiatura elettrica statica ad uso intensivo, progettata con precisione per gestire livelli estremi di tensione, tipicamente compresi tra 66 kV e oltre 500 kV. Oltre alla semplice conversione, funge da nodo di collegamento critico tra impianti di generazione di potenza multi-gigawatt, linee di trasmissione ultra-alta tensione (UHV) su lunga distanza e cabine di distribuzione regionali. Queste unit\u00e0 sono costruite con integrit\u00e0 strutturale rinforzata e sistemi avanzati di isolamento dielettrico per garantire un funzionamento continuo nelle condizioni ambientali e di carico pi\u00f9 gravose.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Principi elettromagnetici di funzionamento<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Basandosi sulla legge di induzione elettromagnetica di Faraday, il trasformatore utilizza corrente alternata nell\u2019avvolgimento primario per generare un flusso magnetico variabile all\u2019interno di un nucleo in acciaio al silicio orientato a grani ad elevata permeabilit\u00e0 magnetica. Questo campo magnetico induce in modo uniforme una tensione matematicamente trasformata nell\u2019avvolgimento secondario \u2014 innalzando o abbassando la tensione, mantenendo inalterata la frequenza elettrica e la massima stabilit\u00e0. I moderni progetti UNICORE incorporano tecnologia di nucleo a gradini e geometria ottimizzata degli avvolgimenti per ridurre al minimo le perdite per correnti parassitarie ed assicurare un\u2019efficienza di conversione energetica superiore al 99%.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Funzioni fondamentali nella trasmissione di potenza<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La sua funzione finale \u00e8 massimizzare l\u2019efficienza della trasmissione di energia su grandi distanze e topologie di rete complesse. Innalzando drasticamente la tensione per il trasporto su lunga distanza, il trasformatore riduce proporzionalmente la corrente elettrica. Questo processo minimizza <math xmlns=\"http:\/\/www.w3.org\/1998\/Math\/MathML\"><semantics><mrow><msup><mi>I<\/mi><mn>2<\/mn><\/msup><mi>R<\/mi><\/mrow><annotation encoding=\"application\/x-tex\">I<sup>2<\/sup>R<\/annotation><\/semantics><\/math> le perdite di energia (termiche) sulle linee di trasmissione, garantendo un\u2019erogazione stabile, economica e sicura di potenza alle reti degli utenti finali. Inoltre, componenti integrati di regolazione precisa della tensione consentono al trasformatore di compensare attivamente le fluttuazioni di rete, proteggendo le infrastrutture industriali sensibili a valle.<\/p>\n<\/div>\n\n\n\n<div class=\"gb-element-21bc0ec4\">\n<a class=\"gb-text gb-text-df9ead0a\" href=\"#popmake-128\">Richiedi un preventivo gratuito<\/a>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div>\n<div class=\"gb-element-49c29c7a\">\n<div>\n<div class=\"gb-element-f2f73a26\">\n<div>\n<div class=\"gb-element-f4787fa9\">\n<div class=\"gb-carousel gb-carousel-659c1dfd\" data-slides-per-view=\"2\" data-space-between=\"10px\" data-free-mode=\"true\" data-pagination-type=\"progressbar\" data-autoplay-enabled=\"true\" data-carousel-id=\"659c1dfd\">\n<div class=\"gb-carousel-items\">\n<div class=\"gb-carousel-item\">\n<img decoding=\"async\" class=\"gb-media-6bd4f1dc\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/custom-high-voltage-power-solutions-1.jpg\" alt=\"\" title=\"soluzioni personalizzate ad alta tensione (1)\"\/>\n<\/div>\n\n\n\n<div class=\"gb-carousel-item\">\n<img decoding=\"async\" class=\"gb-media-f5876945\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/custom-high-voltage-power-solutions-2.jpg\" alt=\"\" title=\"soluzioni personalizzate ad alta tensione (2)\"\/>\n<\/div>\n\n\n\n<div class=\"gb-carousel-item\">\n<img decoding=\"async\" class=\"gb-media-5fdfc043\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/custom-high-voltage-power-solutions-6.jpg\" alt=\"\" title=\"soluzioni-personalizzate-alta-tensione6\"\/>\n<\/div>\n\n\n\n<div class=\"gb-carousel-item\">\n<img decoding=\"async\" class=\"gb-media-891d5c92\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/custom-high-voltage-power-solutions-8.jpg\" alt=\"\" title=\"soluzioni-personalizzate-alta-tensione8\"\/>\n<\/div>\n\n\n\n<div class=\"gb-carousel-item\">\n<img decoding=\"async\" class=\"gb-media-3cb355de\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/custom-high-voltage-power-solutions-5.jpg\" alt=\"\" title=\"soluzioni-personalizzate-di-alimentazione-ad-alta-tensione5\"\/>\n<\/div>\n\n\n\n<div class=\"gb-carousel-item\">\n<img decoding=\"async\" class=\"gb-media-3e52bdd1\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/custom-high-voltage-power-solutions-4.jpg\" alt=\"\" title=\"soluzioni-personalizzate-di-alimentazione-ad-alta-tensione4\"\/>\n<\/div>\n\n\n\n<div class=\"gb-carousel-item\">\n<img decoding=\"async\" class=\"gb-media-c84e1ae4\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/custom-high-voltage-power-solutions-7.jpg\" alt=\"\" title=\"soluzioni-personalizzate-di-alimentazione-ad-alta-tensione7\"\/>\n<\/div>\n\n\n\n<div class=\"gb-carousel-item\">\n<img decoding=\"async\" class=\"gb-media-7e03729b\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/custom-high-voltage-power-solutions-3.jpg\" alt=\"\" title=\"soluzioni personalizzate di potenza ad alta tensione (3)\"\/>\n<\/div>\n<\/div>\n\n\n\n<div class=\"gb-element-2e9dac67\">\n<div aria-label=\"Progresso della carousel\" aria-valuemax=\"100\" aria-valuemin=\"0\" role=\"progressbar\" class=\"gb-carousel-pagination gb-carousel-pagination-b2ae08f6\" data-pagination-type=\"progressbar\"><span class=\"gb-carousel-pagination-content\"><\/span><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div>\n<div class=\"gb-element-d4a144c3\">\n<p class=\"gb-text gb-text-aa233227\">Perch\u00e9 scegliere Unicore<\/p>\n\n\n\n<h2 class=\"gb-text gb-text-abb8d9b6\">Il vostro partner affidabile nelle soluzioni energetiche<\/h2>\n\n\n\n<img decoding=\"async\" class=\"gb-media-00de2a6f\" alt=\"\" title=\"2\" src=\"https:\/\/unicoreelectric.com\/wp-content\/uploads\/2026\/06\/2-1.png\"\/>\n\n\n\n<div class=\"gb-element-e1c35c34\">\n<p class=\"gb-text\">Quando un trasformatore di potenza ad alta tensione va in avaria, le conseguenze vanno ben oltre l\u2019attrezzatura stessa \u2014 ne derivano ritardi nell\u2019energizzazione, rifiuti da parte degli operatori di rete e sovraccosti del progetto. I trasformatori di potenza ad alta tensione UNICORE sono progettati per eliminare tali rischi, grazie a un\u2019ingegnerizzazione approfondita, a certificazioni riconosciute e a un supporto progettuale all\u2019altezza delle esigenze di approvvigionamento a livello di trasmissione.<\/p>\n\n\n\n<div class=\"gb-element-82ff2bb7\">\n<div class=\"gb-element-1c2b1134\">\n<div class=\"gb-element-746c570b\">\n<div class=\"gb-element-ccc63587\">\n<p class=\"gb-text gb-text-bc30072e\"><strong>Progettato per un servizio di rete a lungo termine<\/strong><\/p>\n<\/div>\n\n\n\n<div>\n<p class=\"gb-text gb-text-4d9d7c9c\">Un design elettromagnetico ottimizzato, nuclei in acciaio al silicio CRGO di prima qualit\u00e0, una struttura del serbatoio rinforzata e processi di riempimento ad olio sotto vuoto di precisione si combinano per garantire prestazioni stabili, ridotta degradazione termica e integrit\u00e0 dielettrica affidabile per decenni di funzionamento continuo nella rete di trasmissione.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"gb-element-b98af914\">\n<div class=\"gb-element-d6032692\">\n<div class=\"gb-element-04f44383\">\n<div class=\"gb-element-aeb20bf6\">\n<p class=\"gb-text gb-text-be0d35b1\"><strong>Pronto per la connessione alla rete da fonti rinnovabili<\/strong><\/p>\n<\/div>\n\n\n\n<div>\n<p class=\"gb-text gb-text-efeaad51\">I trasformatori di potenza ad alta tensione Unicore sono sempre pi\u00f9 specificati per applicazioni di connessione alla rete da impianti solari, eolici e idroelettrici \u2014 dove rapporto di trasformazione preciso, tolleranza alle armoniche e prestazioni a basse perdite sono fondamentali per l\u2019accettazione da parte dell\u2019operatore di rete e per l\u2019efficienza generativa a lungo termine durante l\u2019intero ciclo di vita del progetto.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Trasformatore di potenza I trasformatori di potenza ad alta tensione Unicore sono progettati per le reti di trasmissione e distribuzione primaria, con classi di tensione comprese tra 35 kV e 750 kV \u2014 coprendo applicazioni di innalzamento, abbassamento e trasmissione di potenza su lunga distanza in cabine elettriche, centrali elettriche, parchi industriali e grandi progetti di energia rinnovabile in tutto il mondo. Realizzati intorno a strutture elettromagnetiche ottimizzate, nuclei in acciaio al silicio di alta qualit\u00e0 e serbatoi rinforzati \u2026 <\/p>\n<p class=\"read-more-container\"><a title=\"Trasformatore di potenza ad alta tensione\" class=\"read-more button\" href=\"https:\/\/unicoreelectric.com\/it\/high-voltage-power-transformer\/#more-502\" aria-label=\"Per saperne di pi\u00f9 su Trasformatore di potenza ad alta tensione\">Leggi di pi\u00f9<\/a><\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"generate_page_header":"","footnotes":""},"class_list":["post-502","page","type-page","status-publish","no-featured-image-padding"],"_links":{"self":[{"href":"https:\/\/unicoreelectric.com\/it\/wp-json\/wp\/v2\/pages\/502","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/unicoreelectric.com\/it\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/unicoreelectric.com\/it\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/unicoreelectric.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/unicoreelectric.com\/it\/wp-json\/wp\/v2\/comments?post=502"}],"version-history":[{"count":3,"href":"https:\/\/unicoreelectric.com\/it\/wp-json\/wp\/v2\/pages\/502\/revisions"}],"predecessor-version":[{"id":2321,"href":"https:\/\/unicoreelectric.com\/it\/wp-json\/wp\/v2\/pages\/502\/revisions\/2321"}],"wp:attachment":[{"href":"https:\/\/unicoreelectric.com\/it\/wp-json\/wp\/v2\/media?parent=502"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}